7
•
check if there is no IP address conflict when you connect the device into
network for the first time. The device has from factory set the IP address to
192.168.1.213
. This address must be changed according to information from the
previous point. When you install several new devices, connect them to the
network one after another.
•
remove device cover, connect current loops, and power supply terminals
according to image below.
Inputs channels on the device are not
galvanically isolated. Power supply is not isolated from inputs as well!
Device is isolated from communication line side only. Carefully consider how
connect sensor with current output into your
AR004798
.
•
close device cover
•
connect the Ethernet connector
•
power on the power supply adapter
•
LEDs on LAN connector should blink after connecting the power
AR004798
inputs schematic:
Sensor connection example:
Device settings
•
run configuration software TSensor on your PC
•
switch to an
Ethernet
communication interface
•
press button
Find device...