background image

l

 

38

DP Message Types

NMEA0183R Format

A 42-character string:

$RLS,±AAA.AA,±BBB.BB,S

1

,XXX.XXX,S

2

,HHHH*CC<CR><LF>

Where:

• 

$RLS

 message header

• 

AAA.AA

 resolved raw position in A axis [metres]

• 

BBB.BB

 resolved raw position in B axis [metres]

• 

S

1

 status of position data in A and B axis, A - available; V - void

• 

XXX.XXX

 resolved bearing of vessel with respect to A axis [degrees]

• 

S

2

 status of bearing data, A - available; V - void

• 

HHHH

 status word in hexadecimal. Up to 16 bits defined by Guidance Marine in a 

separate specifications document

• 

CC

 computed checksum in hex

• 

<CR>

 Carriage return (ASCII 0D hex)

• 

<LF>

 Line feed (ASCII 0A hex)

NMEA0183P Format

A 42 character string:

$RLS,±AAA.AA,±BBB.BB,S

1

,XXX.XXX,S

2

,HHHH*CC<CR><LF>

Where:

• 

$RLS

 message header

• 

AAA.AA

 resolved primary position in A axis [metres]

• 

BBB.BB

 resolved primary position in B axis [metres]

• 

S

1

 status of position data in A and B axis, A - available; V - void

• 

XXX.XXX

 resolved bearing of vessel with respect to A axis [degrees]

• 

S

2

 status of bearing data, A - available; V - void

• 

HHHH

 status word in hexadecimal. Up to 16 bits defined by Guidance Marine in a 

separate specifications document.

• 

CC

 computed checksum in hex

• 

<CR>

 Carriage return (ASCII 0D hex)

• 

<LF>

 Line feed (ASCII 0A hex)

When the targets are installed on a fixed platform and their co-ordinates are 
entered in Northings and Eastings, AAA.AA and BBB.BB will also be in Northings 
and Eastings and XXX.XXX will be true vessel heading.

Содержание CyScan

Страница 1: ...ness Park Leicester LE19 1RP UK T 44 116 229 2600 E sales guidance eu com www guidance eu com www marine direct CyScan Installer s Guide featuring CyScan Service Interface W A R R A N T Y See our stan...

Страница 2: ...transferred copied or reproduced in whole or in part in any manner or form or in or on any media to any person other than in accordance with the terms of the Owner s Agreement or otherwise without th...

Страница 3: ...talling CyScan Client Software onto a Type 2 or 3 Marine Processor 23 Installing CyScan Client Software onto other Types of Computer 24 Configuring the CyScan System 25 Using the CyScan Service Interf...

Страница 4: ...ics 54 The Kongsberg Maritime CyScan Sensor 55 DP Message Types 55 Kongsberg Custom 55 Client and DP Feed Connections Ethernet Client Serial DP 56 Client and DP Feed Connections Ethernet Client Dual S...

Страница 5: ...des an introduction and overview of the CyScan system It contains the following sections Welcome page 6 System Overview page 7 CyScan Sensor Part Names page 8 Serial Numbers Software Versions page 10...

Страница 6: ...n Operator s Guide Doc 94 0353 4 Note that the introduction of the CSI constitutes a significant change in the CyScan configuration interface in comparison with the legacy console There may also be fu...

Страница 7: ...igure control and monitor the CyScan system They are installed on one or more marine specification Type 2 Marine Processor or other computers running Microsoft WindowsTM usually mounted on the bridge...

Страница 8: ...he diagram below shows the key parts of the sensor unit and the various names that are used throughout this guide Client Data Power DP Feed Optical Window Rotor Base Plate Sensor Information Display A...

Страница 9: ...l 9 CyScan Sensor Part Names Continued Alternative model with 4 cable glands Client Data Power DP Feed 2 DP Feed 1...

Страница 10: ...tion service support call to the company Software Version Information The About tab of the CyScan Service Interface displays software version information and the sensor serial number CyScan Sensor Pro...

Страница 11: ...ver application Ctrl App Version V4 9 3 87 Displays the software version number for the Controller application Rec Boot Version V4 9 3 87 Displays the software version number for the Receiver boot loa...

Страница 12: ...l 12 Installing the Sensor Hardware This section contains the following pages Where to Mount the Sensor page 13 Sensor Dimensions and Mounting Template page 14...

Страница 13: ...all directions from any radar Clear of likely emissions from exhausts or other particulate sources to reduce the need for cleaning the optical windows The sensor should be mounted with the Access Pla...

Страница 14: ...ess plate Allow 300mm clearance at the access plate to manoeuvre internal assemblies in out Allow 150mm clearance at either side of the unit for use of the lifting handles Allow 150mm clearance for ac...

Страница 15: ...cifications page 16 UPS Specifications page 17 CyScan Sensor Connections page 18 Client and DP Feed Connections Ethernet Client Serial DP page 19 Client and DP Feed Connections Ethernet Client Dual Se...

Страница 16: ...Serial Signal Wiring to DP System Minimum 5 core shielded data cable 33 0122 3 Olflex Classic 135 CH xG 0 5 All cables should be external marine standard including UV and chemical resistance 500V rate...

Страница 17: ...nt draw at 240V 0 52A RMS Nominal Current draw at 240V 0 4A RMS Type 2 Marine Processor Power Adaptor Voltage Range 100 240V Frequency Range 50 60Hz Peak Current draw 1 5A RMS The CyScan UPS should be...

Страница 18: ...the access plate and remove the plate from the sensor unit to expose the connector board See CyScan Sensor Part Names on page 8 2 Remove the screw head from the appropriate watertight cable gland See...

Страница 19: ...ns Contact Guidance Marine if alternative settings are required To Connect Cables to Power Serial Plugs Hook lever tool into slot above connector hole in plug 3 3 Whilst holding down lever insert cabl...

Страница 20: ...required Ferrite Bead Ethernet 1 Ethernet 0 Serial 0 Serial 1 Power Power LED VFD Screen Fuses Stern Bow Service Connections RS422 Link 9600 baud 8 bits 1 stop bit No parity Ethernet Link to Client Co...

Страница 21: ...Stern Bow Service Connections RS422 Link 9600 baud 8 bits 1 stop bit No parity 1 2 3 4 5 6 7 8 9 1 RX 2 RX 3 TX 4 TX 5 GND 6 Test 7 GND 8 24V CyScan Serial 0 Type 2 Marine Processor COM6 RS422 Link 3...

Страница 22: ...rine Processor as a replacement for a Marine PC 94 0298 4 Type 2 Marine Processor Installation Sheet Marine PC Replacement For a Type 3 Marine Processor 94 0465 4 Type 3 Marine Processor and Display I...

Страница 23: ...button The installation process for the Dashboard is complete following the restart 8 Click on the Close button on the CyScan Dashboard Setup window 9 Repeat steps 2 8 for CyScanServiceInterfaceSetup...

Страница 24: ...mpts To Install the CyScan Client Software 1 Locate the files CyScanDashboardSetup exe and CyScanServiceInterfaceSetup exe on the USB memory stick on which they were supplied 2 Double click on the CyS...

Страница 25: ...his section contains the following pages Using the CyScan Service Interface page 26 Network Communication Settings page 27 Vessel Calibration page 28 Static Blanking Zones page 30 DP Feed Configuratio...

Страница 26: ...llowing fields and control buttons Connected State Whether the CSI is Connected to the sensor or Disconnected Sensor State Running or Suspended when the CSI is connected Unknown when not connected Sus...

Страница 27: ...ake Command button if the CSI is not already In Command mode 3 Click on Browse 4 Locate the connect ini file within the Select a sensor network configuration file window and click on Open 5 Click on S...

Страница 28: ...utside the recommended range of 2 5 Display Vessel Orientation The default direction of the vessel bow as displayed on the Bird s Eye View of the Dashboard Changing this setting rotates the whole BEV...

Страница 29: ...om an XML or CTF file or exported to an XML file To Reset to Factory Defaults 1 Ensure that no target tracking is in progress 2 Click on the Take Command button if the CSI is not already In Command mo...

Страница 30: ...Service Interface and the static blanking zones cannot be amended via the Dashboard Viewing the Static Blanking Zones The Blanking tab of the CSI displays each of the configured zones and their Start...

Страница 31: ...with the most recent message emitted See DP Message Types page 38 for details of each available message format and DP Feed Behaviour page 32 for the function of the Keep Feed Enabled and Allow Zero St...

Страница 32: ...st Flag indicates stale data data is stale for 10sec then zero Flag indicates stale data data is stale for 10sec then zero Flag indicates stale data data is stale for 10sec then zero Flag indicates st...

Страница 33: ...f parameters can be viewed but not edited To Edit System Parameters 1 Ensure that no target tracking is in progress 2 Click on the Take Command button if the CSI is not already In Command mode 3 On th...

Страница 34: ...a File 1 Ensure that no target tracking is in progress 2 Click on the Take Command button if the CSI is not already In Command mode 3 On the Parameters tab click on the Import button 4 Browse to locat...

Страница 35: ...page 38 Part Numbers page 42 CyScan MkIV Installation Checklist page 43 Cable Routing Diagrams page 44 Sensor Information Display Error Messages page 50 Upgrading the Sensor Software Via the Remote In...

Страница 36: ...t number 20 0031 0 2m x 350mm flat reflector including stainless steel bands Cylindrical Targets Cylindrical targets can be used up to approximately 300 metres They can be hung over the side of the st...

Страница 37: ...eam should not strike a flat target at an angle of more than 45 degrees to the target surface Cylindrical targets can be viewed from any angle equally well Optimum Spacing for Multiple Targets Targets...

Страница 38: ...ex NMEA0183P Format A 42 character string RLS AAA AA BBB BB S1 XXX XXX S2 HHHH CC CR LF Where RLS message header AAA AA resolved primary position in A axis metres BBB BB resolved primary position in B...

Страница 39: ...s nnn nn 17 Space 0x20h X 18 19 NMEA style checksum in hex CC 20 carriage return 0x0Dh X 21 line feed 0x0Ah X DP Message Types Continued Nautronix Standard A 14 character string delimited only by CR a...

Страница 40: ...Responder ID 1 5 or RadaScan 16 bit Responder ID 1 5 chars S Status V oid or N avigating 1 char RRR R RR Range in metres 4 7 chars ZR ZRZR Range standard deviation in metres 4 chars BB B BB Bearing in...

Страница 41: ...s S Status V oid or N avigating 1 char RRR R RR Range in metres 4 7 chars ZR ZRZR Range standard deviation in metres 4 chars BB B BB Bearing in degrees clockwise from bow 4 6 chars ZB ZBZB Bearing sta...

Страница 42: ...ine Processor 20 0155 0 Monitor Bracket Cables Various Keyboard 38 0038 4 Mouse 38 0037 4 Power Cable 40m 33 0121 3 Data Cable 40m 33 0122 3 Ethernet Cable 40m 33 0124 3 Ethernet Connector Plug 80 009...

Страница 43: ...Hz DP feed correctly wired Client s correctly wired Client s Supplied by UPS 85 264VAC 47 63Hz Client s correctly wired Cables Serial capable of 38400 baud Ethernet capable of 10Mbit sec System System...

Страница 44: ...trument Room Bridge Mast Ethernet Sensor Power RS 422 Data Power Cable P N 33 0121 3 40m Data Cable P N 33 0122 3 40m Ethernet Cable P N 33 0124 3 40m 16A 5A 5A DP System UPS DP System Interface Cabin...

Страница 45: ...can Sensor CyScan Client Computer Link Cable CyScan Client DP Feed Power Ethernet Client Serial DP Separate Connection Box CyScan Monitor Monitor Power Cable Monitor Cable Connection Box Power Adaptor...

Страница 46: ...CyScan Client DP Feed Power Ethernet Client Dual Serial DP CyScan Monitor Monitor Power Cable Monitor Cable DP System 2 Interface Cabinet RS 422 Data Data Cable P N 33 0122 3 40m Cable Routing Diagram...

Страница 47: ...er CyScan Monitor Monitor Power Cable Monitor Cable DP Instrument Room Bridge Mast Emergency Breaker Box 5A Link Cable CyScan Client DP Feed Power Cable Routing Diagrams Continued Power Adaptor Marine...

Страница 48: ...ace Cabinet CyScan Sensor CyScan Client Computer CyScan Monitor Monitor Power Cable Monitor Cable DP Instrument Room Bridge Mast Emergency Breaker Box 5A Link Cable CyScan Client DP Feed Power Cable R...

Страница 49: ...r 20 0155 0 or Type 3 Marine Processor Part Number 20 0220 4 Monitor Hatteland Marine Touchscreen Monitor Part Number 20 0211 4 Optional brackets Hatteland Mounting Bracket Part Number 24 0259 4 Hatte...

Страница 50: ...for the sensor to reboot Download timed out The link between the system and boot loader has failed Err writing sw event There was an error writing a period software event to the system Failed Programm...

Страница 51: ...cessful Receiver Fatal Error The receiver has generated a fatal alarm and cannot start Running The sensor is in the normal running state Starting application The main sensor is starting Starting motor...

Страница 52: ...file CyScan Installer Remote exe on the USB memory stick on which the CyScan software was supplied 3 Double click on the CyScan Installer Remote exe file 4 In the CyScan Installation Configuration win...

Страница 53: ...grade key 1 Insert the upgrade key into USB0 2 Power cycle the sensor 3 The upgrade will then begin and the system will transfer all the required files to the sensor The Sensor Information Display wil...

Страница 54: ...that are not Reserved Field Delimiters CC Second Checksum Checksum with as the start character Where s PGNMD and are fixed values and are Reserved Field Delimiters denotes a space character ASCII 0x2...

Страница 55: ...tandard Deviation in meters 3 chars BBB B Bearing in degrees 5 chars ZB ZB Bearing Standard Deviation in degrees 3 chars HHHH Status 16 bit code 4 chars Delimiter 1 char CC Checksum 2 chars LF Line fe...

Страница 56: ...e Connections To Connect Cables to Power Serial Plugs Hook lever tool into slot above connector hole in plug 3 3 Whilst holding down lever insert cable end into connector hole Release and remove the l...

Страница 57: ...ns RS422 Link 9600 baud 8 bits 1 stop bit No parity Ethernet Link to Client Computer To Connect Cables to Power Serial Plugs Hook lever tool into slot above connector hole in plug 3 3 Whilst holding d...

Страница 58: ...nt Computer To Connect Cables to Power Serial Plugs Hook lever tool into slot above connector hole in plug 3 3 Whilst holding down lever insert cable end into connector hole Release and remove the lev...

Страница 59: ...8 Targets 7 CyScan Service Interface 26 D Data Cable 16 Diagnostic exit 50 Diagnostics Accessing 54 Download timed out 50 DP Feed 8 9 DP Message Types 38 Dual Serial DP 20 57 E Err writing sw event 50...

Страница 60: ...nsions 14 Part Names 8 Upgrade 53 Sensor Information Display 11 Error Messages 50 Serial Numbers 10 Serial Sensor Connections 21 58 Shielded 16 Signal Wiring 16 Software Versions 10 Standard Component...

Страница 61: ...elease of CyScan Dashboard Installer s Guide 15th October 2013 94 0363 4 B Updated for CyScan v4 83 31st March 2014 94 0363 4 C Inclusion of the Marine brand and the 3 year warranty 31st May 2014 94 0...

Страница 62: ......

Отзывы: