l
20
To Connect an Ethernet Sensor with Ethernet to the Client and Serial to Two DP Systems:
Connect
Ethernet Port 0
to the
Client computer, Serial Port 0
to
DP System 1
and
Serial Port 1
to
DP system 2
.
Configure the serial connections as shown below:
1 RX-
2 RX+
3 TX-
4 TX+
5 GND
6 Test
7 GND
8 +24V
DP
Feed 2
RS422
Link to DP
System 1
Mains Power
85–264V AC
45–65Hz 45W
*
Serial 1
*
+24V output on pin 8
of both serial ports can
be used to power a
100mA data converter,
if required.
Ferrite Bead
Ethernet 1
Ethernet 0
Serial 0
Serial 1
Power
Power LED
VFD Screen
Fuses
Stern
Bow
Service Connections
RS422 Link
9600 baud
8 bits
1 stop bit
No parity
Ethernet
Link to
Client
Computer
To Connect Cables to
Power/Serial Plugs:
.
.
Hook lever-tool into
slot above
connector-hole in
plug.
.
3
Whilst holding
down lever, insert
cable end into
connector-hole.
.
$
Release and remove
the lever-tool.
RS422
Link to DP
System 2
1 RX-
2 RX+
3 TX-
4 TX+
5 GND
6 Test
7 GND
8 +24V
DP
Feed 1
*
Serial 0
Client and DP Feed Connections - Ethernet Client, Dual Serial DP
Client Network Protocol:
Ethernet
Default Ethernet Settings:
†
IP Address: 192.168.0.86
Subnet Mask:
255.255.255.0
Содержание CyScan