CyScan Sensor Connections
Connecting the Power Cable
1. Having fed the cable through the watertight cable gland, use the key provided to open
the ferrite and pass the cable through the centre of the ferrite.
2. Close the ferrite securely and ensure it is firmly attached to the inside of the CyScan
casing to prevent excessive movement.
3. Strip 10mm of insulation from the end of each of the three cable cores.
4. Connect the 3 cores to the appropriate terminals as labelled on the terminal block
(see right).
5. When you have connected the cores to the terminal block, use two cable ties to secure
the terminal block and cable together.
6. Plug the terminal block securely in to the socket on the connector board as shown on
the right.
Earth
Live
Neutral
To Connect a Cable to the CyScan Sensor
1. Remove the 4 screws from the access plate and remove the plate from the sensor unit
to expose the connector board. (See
on page 8).
2. Remove the screw head from the appropriate watertight cable gland. See
on page 8 to identify the correct cable gland.
3. Feed the cable through the screw head and gland.
4. Connect the cable to the correct socket/terminal on the sensor connector board.
5. When all the connections have been made, replace the access plate and tighten all of
the cable glands to ensure a watertight seal.
Base of CyScan with the access plate removed to expose the connector board
Watertight
cable gland
Ferrite
and key
Ferrite Key
Ferrite secured around cable
Power terminals on
connector board
Terminal block with cable cores
connected
Cable ties
To Connect Cables to
Power/Serial Plugs:
.
.
Hook lever-tool into
slot above
connector-hole in
plug.
.
3
Whilst holding down
lever, insert cable
end into connector-
hole.
.
$
Release and remove
the lever-tool.
BOW/STERN switch