Cable Specifications
The CyScan system is usually supplied without the cables that are necessary to connect the sensor to the DP system and the Client Software computer(s). Guidance recommends that
flexible multicore cables are used in all applications. Cables should meet the requirements of IEC 60228 Class 2 or Class 5. Cables must be supplied and fitted by the installer to match the
particular requirements for each vessel. All cables should be properly secured.
The cable glands will fit cables from 7-13mm diameter.
Use
Description
Guidance Marine Limited Part Numbers (40m lengths)
Serial Signal Wiring to DP
System
Minimum 5-core shielded data
cable.
33-0122-3
Olflex Classic 135 CH
xG
0.5
All cables should
be external marine
standard including
UV and chemical
resistance, 500V
rated voltage,
Diameter 7-13mm
and operate between
-40°C to +80°C.
Serial Signal Wiring
to Client Software
Computer(s)
Ethernet Connection
to Client Software
Computer(s)
Standard CAT 5e screened cable
(maximum length 90m).
33-0124-3
Power Cable
3 core cable.
33-0121-3
Olflex Classic 400 CP 3G 1.0
x
is number of cores including
G
round with each core 0.5mm
2
(minimum 5-core specifies 4 signal cores and 1 ground core).
Data cables should not be run across or next to power cables to avoid signal interference problems.
Refer to the cable routing diagrams on page 44 to determine which cables you require.