snmp port show
show s SNMP UDP port
snmp snmpget enabled set {OFF=0|ON=1}
enables SNMP GET cmds on/off
snmp snmpget enabled show
show if SNMP GET cmds are enabled
snmp snmpset enabled set {OFF=0|ON=1}
enables SNMP SET cmds on/off
snmp snmpset enabled show
show if SNMP SET cmds are enabled
snmp snmpv2 enabled set {OFF=0|ON=1}
enables SNMP v2 on/off
snmp snmpv2 enabled show
show if SNMP v2 is enabled
snmp snmpv2 public set "{text}"
enables SNMP v3 on/off
snmp snmpv2 public show
show if SNMP v3 isenabled
snmp snmpv2 private set "{text}"
sets SNMP v2 public cummnity
snmp snmpv2 private show
show s SNMP v2 public community
snmp system {CONTACT=0|NAME=1|
LOCATION=2} set "{text}"
sets sysLocation/sysName/sysContact
snmp system {CONTACT=0|NAME=1|
LOCATION=2} show
gets sysLocation/sysName/sysContact
snmp snmpv3 enabled set {OFF=0|ON=1}
sets SNMP v2 private community
snmp snmpv3 enabled show
show s SNMP v2 private community
snmp snmpv3 username set "{text}"
sets SNMP v3 username
snmp snmpv3 username show
show s SNMP v3 username
snmp snmpv3 authalg set {NONE=0|MD5=1|
SHA1=2|SHA256=3|SHA384=4|SHA512=5}
sets SNMP v3 authentication
snmp snmpv3 authalg show
show SNMP v3 authentication algorithm
snmp snmpv3 privalg set {NONE=0|DES=1|
3DES=2|AES128=3|AES192=4|AES256=5|
AES192*=6|AES256*=7}
sets SNMP v3 privacy algorithm
snmp snmpv3 privalg show
show SNMP v3 privacy algorithm
snmp snmpv3 authpassw d set "{passw d}"
sets SNMP v3 authentication passw ord
snmp snmpv3 privpassw d set "{passw d}"
sets SNMP v3 privacy passw ord
snmp snmpv3 authpassw d hash set "{passw d}" sets SNMP v3 authentication hashed passw ord
snmp snmpv3 privpassw d hash set "{passw d}" sets SNMP v3 privacy hashed passw ord
snmp trap type set {NONE=0|V1=1|V2=2|V3=3}
sets type of SNMP traps
snmp trap type show
show SNMP trap type
snmp trap receiver {trap_num} set "{dns_name}"
sets address and port of SNMP trap receiver
{trap_num}
snmp trap receiver {trap_num} show
show address and port of SNMP trap receiver
{trap_num}
syslog
enters cmd group "syslog"
syslog enabled set {OFF=0|ON=1}
enables syslog msgs on/off
syslog enabled show
show if syslog enabled
syslog server set "{dns_name}"
sets address of syslog server
syslog server show
show s address of syslog server
system
enters cmd group "system"
system beeper manual set {OFF=0|ON=1}
{millisec}
manually sets beeper w ith optional duration
system beeper manual show
show s beeper state
system restart
restarts device
system fabsettings
restore fab settings and restart device
system bootloader
enters bootloader mode
system flushdns
flush DNS cache
system uptime
number of seconds the device is running
system name show
show s device name
system version show
show s actual firmw are version
system display {disp_num} default extsensor
{port_num} {sen_type} set {sen_field}
show s external sensor
system display {disp_num} default linesensor
{line_num} set {sen_field}
show s energy line sensor
system display {disp_num} default portsensor
{port_num} set {sen_field}
show s energy port sensor
system display {disp_num} default set
{BLANK=0,LOCAL_TIME=1,UTC_TIME=2}
show s other contents
system display {disp_num} default show
show s default setting for display
system display default hash set "{data}"
sets hashed display setting
system display default hash show
show s hashed display setting