84
Expert Power Control 8041/8045
© 2022 GUDE Systems GmbH
Specifications
system flushdns
flush DNS cache
system uptime
number of seconds the device is running
system name show
show s device name
system version show
show s actual firmw are version
system display {disp_num} default extsensor
{port_num} {sen_type} set {sen_field}
show s external sensor
system display {disp_num} default linesensor
{line_num} set {sen_field}
show s energy line sensor
system display {disp_num} default set
{BLANK=0,LOCAL_TIME=1,UTC_TIME=2}
show s other contents
system display {disp_num} default show
show s default setting for display
system display default hash set "{data}"
sets hashed display setting
system display default hash show
show s hashed display setting
system {SWITCH_PORT=0} events set {OFF=0|
ON=1}
enable global events
system {SWITCH_PORT=0} events show
show s if global events enabled
system {SWITCH_PORT=0} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
enables different event types
system {SWITCH_PORT=0} events type show
show s w hat event types are enabled
system {SWITCH_PORT=0} events mqtt retain set
{OFF=0|ON=1}
sets mqtt retain
system {SWITCH_PORT=0} events mqtt retain
show
show s if mqtt retain set
system panel enabled set {OFF=0|ON=1}
blocks panel buttons w hen not enabled
system panel enabled show
show s if panel buttons are enabled
system panel port all set {OFF=0|ON=1}
enable siw tch all relays from panel buttons
system panel port all show
show s if siw tch all relays from panel buttons
enabled
system sensor {VSYS=0|VAUX=1|VMAIN=2|
TCPU=3} show
show s internal sensors if model supports it
timer
enters cmd group "timer"
timer enabled set {OFF=0|ON=1}
enables timer functions
timer enabled show
show s if timer a enabled
timer syslog facility set {0..23}
sets facility level for timer syslog
timer syslog facility show
show s facility level for timer syslog
timer syslog verbose set {0..7}
sets verbose level for timer syslog
timer syslog verbose show
show s verbose level for timer syslog
timer {rule_num} enabled set {OFF=0|ON=1}
enables rule
timer {rule_num} enabled show
show s if rule is enabled
timer {rule_num} name set "{name}"
sets name of rule
timer {rule_num} name show
show s name of rule
timer {rule_num} {FROM=0|UNTIL=1} set "{yyyy-
mm-dd}"
sets date range of rule
timer {rule_num} {FROM=0|UNTIL=1} show
show s date range of rule
timer {rule_num} trigger jitter set {0..65535}
sets jitter for rule
timer {rule_num} trigger jitter show
show jitter of rule
timer {rule_num} trigger random set {0..100}
sets probability for rule
timer {rule_num} trigger random show
show s rule probability
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} set "{time_date_list}"
sets time date list
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} show
show s time date list
timer {rule_num} action mode set {SWITCH=1|
CLI=2}
sets sw itch or cli cmd
timer {rule_num} action mode show
show s if sw itch or cli cmd
timer {rule_num} action {SWITCH1=0|SWITCH2=1}
{OFF=0|ON=1} set "{port_list}"
sets port list for sw itch cmd
timer {rule_num} action {SWITCH1=0|SWITCH2=1}
{OFF=0|ON=1} show
show s port list for sw itch cmd
timer {rule_num} action delay set {0..65535}
delay betw een cmds
timer {rule_num} action delay show
show s delay betw een cmds
Содержание Expert Power Control 8041 Series
Страница 2: ...2 Expert Power Control 8041 8045 2022 GUDESystems GmbH ...
Страница 5: ...Device Description ...
Страница 14: ...Operating ...
Страница 25: ...Configuration ...
Страница 54: ...Specifications ...