11
• Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21ºC to +71 ºC). Use of heater bands on arm and
control box will enhance performance in extreme cold temperatures.
• Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm. Generates
1,120 ft. lbs of torque at 12 V.
• Maximum opening arc of 110º. Approximate opening time (90º): 22 seconds, depending on weight of gate.
POWER
• The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 120 Vac, 18 Vac output transformer rectified to 14.5 Vdc (40 VA) through the GTO
control board. Blade-style control board fuse is rated for 25 A.
NOTE: The transformer should not be
directly
connected to any battery. Do not replace fuses
with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
• Battery charge is maintained by
GTO Solar Panel Charger: float voltage of 14.5 Vdc output. Generates minimum of
15 W at 900 mA. A gated diode on the control board prevents battery discharge.
CONTROL
•
GTO
microprocessor-based control board is set for dual leaf, pull-to-open gate installations. DIP switches can be
adjusted to accommodate an optional kit for push-to-open gates (
see Accessory Catalog
).
• Control board has temperature compensated circuits.
• A circuit on the control board regulates charging. "Sleep draw" is 40 mA; "active draw" is 5 to 9 A.
• Auto-memorization of digital transmitter code.
•
GTO remote-mounted RF receiver tuned to 318 MHz.
• Operator length with push-pull tube fully retracted is 46
1
/
4
", mounting point to mounting point, arm stroke 22" max.
• Minimum gate length is 8 ft.
• Adjustable auto-close timer (15 to 120 s), and obstruction sensitivity.
• Power terminal block accommodates a transformer and solar panels.
• DIP switches simplify setup of gate operator.
• Accessory terminal block fully compatible with push button controls, digital keypads, safety loops, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO® 4000XL/4200XL
Automatic Gate Operators when powered with a transformer. Actual cycles may vary slightly depending upon the type
and condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications
listed on
page 22
or call
(800) 543-1236
or
(850) 575-4144
for more information.
* An operation cycle is one full opening and closing of the gate.
GTO/PRO® 4000XL/4200XL AUTOMATIC GATE OPERATOR
Technical Specifications
These specifications are subject to change without notice.
DRIVE
Gate Weight
Gate Length
Gate Capacity Chart GTO/PRO 4200XL
Estimated number of cycles are based on use with a transformer and one(1) 12 Volt battery on a dual gate system.
20 ft.
16 ft.
12 ft.
8 ft.
67
70
72
75
300 lb.
65
67
70
72
400 lb.
62
65
67
70
500 lb.
60
62
65
67
600 lb.
57
60
62
65
700 lb.
55
57
60
62
800 lb.
52
55
57
60
900 lb.
50
52
55
57
1000 lb.