33
Step 3
Note which gate has reached the desired open position (typically it's the slave gate), program the open limit setting by
pressing and holding the corresponding 'LEARN MAST LIMIT' or 'LEARN SLV LIMIT' button for 5 seconds.
Step 4
Press the transmitter button and allow the gates to return to the closed position. YOUR FIRST GATE’S OPEN POSITION
LIMIT IS NOW PROGRAMMED.
Step 5
Activate your openers again by pressing the
entry transmitter button. Your gates should now
be moving from the closed positions toward
their open positions. The first gate will stop at
the spot you just programmed and the second
gate will continue to open until you press the
transmitter button again. Press the transmitter
button when the second gate reaches the desired
open position. This step may be repeated until
desired open position is achieved. Once the
desired OPEN position has been achieved,
proceed to step 6.
Step 6
Repeat step 3 for the other gate that has not been
set in step 3. Note which gate has reached the
desired open position (typically it's the slave
gate), program the open limit setting by pressing
and holding the corresponding 'LEARN MAST
LIMIT' or 'LEARN SLV LIMIT' button for 5
seconds.
Step 7
Press the transmitter button and allow the gates
to return to the closed position. BOTH YOUR
MASTER AND SLAVE GATE’S OPEN POSITION LIMITS ARE NOW PROGRAMMED.
TESTING YOUR OPEN LIMIT SETTING:
Press your entry transmitter and allow your gates to open. If OPEN positions are not correct or need to be changed, you will
need to CLEAR your OPEN LIMIT settings and follow steps one (1) to seven (7) again.
CLEARING THE PROGRAMMED OPEN LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their closed
positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN SLV LIMIT' button for 5 seconds. This will clear the
1
2
3
4
O
N
D
IP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
ART OFF
G OFF
PULL
EN DLY.
OFF
OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
CLOSE TIME
STALL FORCE
Learn Master Limit
Button
Learn Slave Limit
Button