![GTO SW-4000XL Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/gto/sw-4000xl/sw-4000xl_installation-manual_2276241042.webp)
38
Column Installation Information
I
F THIS OPERATOR WILL BE USED WITH GATES THAT ARE MOUNTED ON
MASONRY, BRICK, OR ROCK (etc.) COLUMNS:
READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING
A.
The simplest solution is to install the operator in a push-to-open configuration. The minimum clearance is easier
to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from the column
instead of pulling it toward the column. It is recommended that you place a steel plate between the operator
mounting brackets and masonry surface for additional strength.
B.
If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate.
You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back
corner of the columns.
C.
The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is
NOT
for the inexperienced!
Column
Pivot Bracket
Gate
A
B
Column Mount Example
(A + B can not exceed 19 inches)
Example: If A is 2" then B can not exceed 17"
Hinge