CHAPTER 12 SPECIFICATION
91
*
For 750W/1500W, complied with the rated power output while input AC115V or 230V; For 3000W, complied with the rated
power output while input AC230V; please decrease to lower output power when the input voltage is lower than the
specific volts. For example the 750W models, it can be full power output when input with 115Vac, but reduces to 600W when
input as low as 90Vac.
*
After 30 minutes of turning on the DC power supply, the temperature should be 23±5
°C
, the humidity should be under
80%R.H, AC voltage±5%, and THD≤2%, not using the remote compensating, not operate in series or parallel.
*
Specifications subject to change without notice.
Notes:
*1. The actual output voltage should be ≤0.1% of the rated voltage when the output voltage sets to zero.
*2. The actual output current should be ≤0.2% of the rated current when the output current sets to zero (resistance load).
*3. Measured when output 10%~100% load.
*4. For 6V model: measured when output voltage 2~6V; the other models measured when output 10~100% of rated voltage.
*5. Input voltage: 750W/1500W models: 100~240Vac (50/60Hz) or 3000W models: 190~240Vac (50/60Hz), static load.
*6. Static input voltage and output from no load to full load.
*7. Static input voltage and output from no load to full load.
*8. The output voltage varies from 10%~90% or 90%~10%, rated input voltage, resistive load.
*9. Remote sensing compensation: no compensate if exceed the specified voltage. For example: DSP-100-07.5HD,
Output setting 99V, the wire’s power drop 2V. The remote sensing compensation is 1V, which means the voltage is
98V at load side.