CHAPTER 10 LAN / GPIB / RS-485 COMMAND INTRODUCTION
82
10-4-49. SOURce:LIST:RTIMe? QUERY
Syntax:
Short Form: SOUR:LIST:RTIM?
Long Form: SOURce:LIST:RTIMe?
Description:
Indicates (in seconds) how long output voltage takes to reach programmed value.
Return Format:
<NRf+>
Example:
SOURce:LIST:RTIMe? returns 3.0 to indicate ramp-up time is 3.0 seconds
10-4-50. SOURce:LIST:DTIMe COMMAND
Syntax:
Short Form: SOUR:LIST:DTIM <NRf+>
Long Form: SOURce:LIST:DTIMe <NRf+>
Description:
Sets the output voltage ramp-dwon time.
Argument:
<NRf+> is a value in the range from 0.0 to 99.9 seconds.
Example:
SOURce:LIST:RTIMe 3.0 programs the output ramp-down time to 3.0 seconds.
10-4-51. SOURce:LIST:DTIMe? QUERY
Syntax:
Short Form: SOUR:LIST:DTIM?
Long Form: SOURce:LIST:DTIMe?
Description:
Indicates (in seconds) how long output voltage takes to reach programmed value.
Return Format:
<NRf+>
Example:
SOURce:LIST:RTIMe? returns 3.0 to indicate ramp-down time is 3.0 seconds
10-4-52. SOURce:MEMory:CLS COMMAND
Syntax:
Short Form: SOUR:MEM:CLS
Long Form: SOURce:MEMory:CLS
Description:
Clears all memory locations used for storing and recalling power supply settings.
Argument:
None
Example:
SOURce:MEMory:CLS clears all memory locations.
10-4-53. SOURce:MEMory:RECall COMMAND
Syntax:
Short Form: SOUR:MEM:REC:<NR1>
Long Form: SOURce:MEMory:RECall:<NR1>
Description:
Restores power supply settings to the voltage and current values stored in memory
location defined by <NR1>. If the output is off, the recalled voltage and current set values
are shown on the front panel Voltage and Current displays. If the output is on, the output
changes to the recalled voltage and current values which are also shown on the front panel
Voltage and Current displays.
Return Format:
<NR1> is a number from 1
to 16 representing one of 16 memory locations
Example:
SOURce:MEMory:RECall:3 sets power supply setpoints to 50V and 2.5A (values
previouslystored via either front panel or SOURce:MEMory:VOLTage:<NR1> and
SOURce:MEMory:CURRent:<NR1>commands). If output is on, output is changed to 50V,
2.5A. If output is off, set values of 50V and 2.5A are displayed on the front panel.