![GSi Protek PD Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/gsi/protek-pd-series/protek-pd-series_user-manual_2275134032.webp)
CHAPTER 7 LOAD CONNECTION DESCRIPTION
32
7-3. OUTPUT CONNECTION WITH REMOTE SENSE
(1) Wiring diagram:
(2) Wiring description:
Refer to the above diagram, the +/- sense wiring is connected to the load side, which means the voltage drop will be
compensated by using the +/- sense. The front panel displayed voltage equals to the voltage of load side. Please
note that the compensation is varied in different models. The above wiring method is recommended to the low noise
loads.
7-4. CONSTANT-VOLTAGE & CONSTANT-CURRENT CURVE
7-4-1. Description of constant current curve:
When the power supply acts to maintain its output current constant, in spite of changes of load, line, temperature
and etc., for the change of load resistance, the output current remains constantly while the output voltage changes
according to whatever necessary amount to accomplish this. (As follows)