83 ENGLISH
Note:
The <PTZ Linking> function is only available for the <VCA Settings> of <IP Cameras>.
6.
Enter the <Record Schedule Settings> interface (Menu > Record > Schedule > Record Schedule) and
then set <VCA> as the <Record Type>. For details, see step 2 in Chapter
5.2 Configuring Recording
and Capture Schedule.
5.6 Manual Recording and Continuous Capture
Follow the steps to set parameters for the manual recording and continuous capture. Using manual
recording and continuous capture, you need to manually cancel the record and capture. The manual
recording and manual continuous capture is prior to the scheduled recording and capture.
Steps:
1.
Enter the <Manual> settings interface: Menu> Manual
Or press the <
REC/SHOT>
button on the front panel.
Manual Record
2.
Enable the Manual Recording.
1)
Select
<Record> on the left bar.
2)
Click the <Status> button before the <Camera Number> to change from
to
.
3.
Disable <Manual Record>.
Click the <Status> button to change from
to
.
Note:
The Green icon
means that the channel is configured for the record schedule.
After rebooting, all
the manual records enabled will be canceled.
4.
Enabling and disabling the continuous capture
1)
Select <Continuous Capture> on the left bar.