Symbol Description

O

Analog and digital outputs

A

Power side

B

Signal side

WIO

WIO sensor, "eb" and "mb" approval

C

"db" enclosure

T

Thermal switch

M

Moisture switch

P

Power input

S

Sensor input

SM 113 Sensor board

IO 113

IO 113 with internal alarm relay (250
VAC)

"db"

Flameproof enclosure of the motor sec-
tion

"mb"

WIO sensor protection by enclosure

"eb"

WIO sensor protection by increased
safety

5.5.1 Thermal switches

The thermal protection against overheating is
ensured with bimetallic switches as standard or
thermistors as optional. The three thermal switches
are hardwired from the pump to the IO 113 or a
similar controller. They open if the stator windings
become overheated. The thermal switches are
reversible and close again when the motor is cooled
down.
This generates both a hardware and a software alarm
in the IO 113, and the alarm relay opens.
The switching current for the thermal switch is 0,5 A
at cos φ 0.6.

The thermal protection of explosion-proof
pumps must not restart the pump automat-
ically.

Install an automatic circuit breaker, which
disconnects the power supply in case the
thermal- or the moisture switches are not
operating.

5.5.2 Moisture switch

The pumps have two moisture switches, one below
the motor top cover and one in the stator housing.
The moisture switches are irreversible and must be
replaced if activated.

The moisture switches are hardwired from the pump
to the IO 113 or a similar controller. They open if
moisture is detected and break an electric circuit. This
generates both a hardware and a software alarm in
the IO 113, and the alarm relay opens.
The switching current on the moisture switch is 6 A.

5.5.3 Pt100

The pumps are equipped with Pt100 sensors in the
stator windings, in the upper- and the lower bearing
bracket.
Pt100 makes an analog measurement from 0-180 °C.
The value is measured by SM 113 and transferred to
IO 113 through serial communication.
If the pump does not have an SM 113, hardwire the
Pt100 sensors out of the pump and connect them to
an external unit. If the pump has an SM 113, connect
the Pt100 sensors to the SM 113. An external unit is
not required.
The maximum alarm temperatures are indicated in
the table below:

Pump
range

Alarm temperatures

Winding tem-

perature

[°C]

Upper

bearing

[°C]

Lower

bearing

[°C]

72

150

120

100

74

150

120

120

78

150

120

120

5.5.4 WIO sensor

All Ex pumps must be factory-fitted with an
internal WIO sensor.

Lack of oil may cause overheating and
damage to the mechanical shaft seals.
The WIO sensor in the oil chamber trips
the alarm if the oil quality or quantity is in-
sufficient in the oil chamber.

Do not use Shell Ondina X420 oil without
emulsifier detergent in pumps fitted with a
WIO sensor.

The oil chamber is filled with oil acting as lubricant
and coolant for both mechanical seals. The WIO
sensor measures the water content in the oil
chamber:

0-20 % water in the oil does not cause a reaction.

Water content outside the measuring range
causes a warning.

Low oil level causes an alarm. The pump must not
operate while this alarm is on.

26

English (GB)

Содержание ST-55-520

Страница 1: ...S pumps ranges 72 74 78 S2 S3 S4 ST 55 520 kW Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ......

Страница 3: ...amiento 241 Suomi FI Asennus ja k ytt ohjeet 283 Fran ais FR Notice d installation et de fonctionnement 321 GR 361 Hrvatski HR Monta ne i pogonske upute 404 Magyar HU Telep t si s zemeltet si utas t s...

Страница 4: ...onta o in obratovanje 831 Sloven ina SK N vod na mont a prev dzku 869 T rk e TR Montaj ve kullan m k lavuzu 908 UA 948 CN 991 Norsk NO Installasjons og driftsinstruksjoner 1026 AR 1063 China RoHS 1099...

Страница 5: ...trol functions 24 5 1 Motor protection devices 24 5 2 Pump controller 24 5 3 IO 113 24 5 4 SM 113 optional 25 5 5 Switches and sensors 25 6 Starting up the product 27 6 1 Preparations for starting up...

Страница 6: ...r mod erate personal injury The hazard statements are structured in the following way SIGNAL WORD Description of the hazard Consequence of ignoring the warning Action to avoid the hazard 1 2 Notes The...

Страница 7: ...tated in the order confirmation and other documentation supplied with the pump Note The pump type described in this manual is not available in all variants Example S2 90 250 2250 4 72S C 496 G N D 513...

Страница 8: ...Frequency Hz 6 60 Hz Code Explanation Designation 0H 3 x 400 V DOL Voltage code and connection 50 Hz 3 3 x 415 V DOL 4 3 x 500 V DOL 6 3 x 660 V DOL 8 3 x 380 400 V DOL 0B 3 x 400 415 V DOL 0D 3 x 38...

Страница 9: ...e delta connection 8 Rated voltage star connection 9 Rated power input output kW 10 Cos 1 1 load 11 Production code year and week 12 Production number 13 Maximum liquid temperature C 14 Maximum flow r...

Страница 10: ...nt category high protection G Type of explosive atmosphere gas CE CE mark UKCA UKCA mark 0344 Number of quality assurance notified body 1180 Number of quality assurance notified body Ex Marking of exp...

Страница 11: ...rk UKCA UKCA mark 0344 Number of quality assurance notified body 1180 Number of quality assurance notified body Ex Marking of explosion protection db Flameproof Zone 1 IIB Gas group Ethylene Tamb Ambi...

Страница 12: ...often have a high er temperature at the cable entries than submerged ones This may re duce the lifetime of the Ex protection equipment According to EN IEC 60079 14 it is a user responsibility to regul...

Страница 13: ...sor must be limited to 350 mA accord ing to EN IEC 60079 18 and 60079 0 5 The WIO sensor must be used with a galvanically isolated circuit 2 7 Applications Depending on the installation type the pumps...

Страница 14: ...a label attached to the transport stand DANGER Electric shock Death or serious personal injury Never lift the pump by the power ca bles Lifting the pump by the power cables may result in electric sho...

Страница 15: ...the pump when raising it to vertical position Make sure the pump is raised carefully into vertical position to avoid the lifting chain slipping off the crane when the pump is unbalanced Carelessness...

Страница 16: ...l work in pits must be supervised by a person outside the pit Pits for submersible sewage and wastewater pumps contain toxic and or contagious substances Therefore all persons must wear appropriate pe...

Страница 17: ...icient rigidity to withstand the axial transverse and torsional loadings generated by the pump The foundation must be 15 cm wider than the base plate or base stand for pumps up to 350 kW and 25 cm wid...

Страница 18: ...L M H 425 Pressure class F 0 Required tilt angle when the pump is lowered onto the auto coupling 5 TM033067 Lowering the pump onto an auto coupling Submerged installation on auto coupling Pumps for p...

Страница 19: ...ng base unit the pump automatically connects 8 Hang up the end of the chain on a suitable hook at the top of the pit Make sure that the chain is straight but not strained 9 Adjust the length of the po...

Страница 20: ...he pump is not stressed by the pipes 6 Adjust the length of the power cables by coiling them up on a relief fitting to ensure that the cables are not damaged during operation Make sure to have enough...

Страница 21: ...cal surfaces prevents the pump from rotating As an additional precaution there are three guide pins on the seat ring which limit the possible rotation to a maximum of 60 5 Hang up the end of the chain...

Страница 22: ...with a motor protection relay with an IEC trip class 10 or 15 Connect pumps installed in hazardous lo cations to a control box with a motor pro tection relay with an IEC trip class 10 The motor is ef...

Страница 23: ...r data Local regulations or standards must be complied with Before installing a frequency converter calculate the lowest frequency allowed in the installation to avoid zero flow Do not reduce the moto...

Страница 24: ...d level is lowered to the middle of the motor housing Install the start level switch so the pump is started at the required level The pump must always be started before the liquid level reaches the bo...

Страница 25: ...er line communication using Grundfos GENIbus protocol S Sensor inputs SM 113 can collect data from the following devices current sensors 4 20 mA Pt100 Pt1000 thermal sensors Vibration sensor water in...

Страница 26: ...ontroller They open if moisture is detected and break an electric circuit This generates both a hardware and a software alarm in the IO 113 and the alarm relay opens The switching current on the moist...

Страница 27: ...ted either direct on line DOL or star delta Y D The selection of starting method depends on usage and main supply conditions In case of star delta starting keep the switching transient time at a minim...

Страница 28: ...ous operation S1 the pump must always be covered by the pumped liquid to the top of the motor See fig Liquid levels Installation type C The pump housing must always be covered by the pumped liquid For...

Страница 29: ...ing sucked into the pump inlet The lowest level cannot always be predicted but must be confirmed through tests during startup 6 2 2 Start and stop levels for dry installations Stop levels The stop lev...

Страница 30: ...ller Installation types S C and ST Proceed as follows 1 Lift the pump approximately 2 5 cm from the ground or base by the lifting chain and a crane 2 Start and run the pump for a few seconds 3 Observe...

Страница 31: ...uct 7 1 Handling the product DANGER Crushing hazard Death or serious personal injury Move the pump only by a forklift or a lifting crane Before lifting the pump make sure the centre of gravity is betw...

Страница 32: ...es 8 Servicing and maintaining the product 8 1 Safety instructions and requirements DANGER Crushing hazard Death or serious personal injury During maintenance and service in cluding transport to servi...

Страница 33: ...m the oil chamber To test the sensor measure the current flowing through it and compare the values to the table below Value Explanation Measurement evalu ation 0 mA Cable break Sensor fault Change the...

Страница 34: ...eir positions relative to each other See fig Pump with inspection screw A upwards A B TM046924 Correct oil level of vertical pump 2 Use screw B for indication of the oil level in the oil chamber See f...

Страница 35: ...cover is located between the pump housing and the outer connection flange at the inlet side of the pump Depending on the construction there are two ways to set the impeller clearance Method 1 Pump ty...

Страница 36: ...2 fastening screw and the distance L as reference 4 Tighten all set screws and check that the distance L at the three reference points is stable at the new value 8 5 Pump cleaning and inspection Clean...

Страница 37: ...ce CAUTION Biological hazard Minor or moderate personal injury Flush the pump thoroughly with clean water and rinse the pump parts after dismantling If a pump is used for a toxic or contagious liquid...

Страница 38: ...fault occurs again find the cause of the overload Check the control panel fuses and switch them on in case they are tripped Wait for approximately 10 minutes until the pump is cooled down and start it...

Страница 39: ...verheated motor causes the thermal switches to trip out Let the pump cool Clean the pump The level switch is out of adjust ment or defective Clean or reset the level switch or replace it as required T...

Страница 40: ...ts 10 1 5 Flow velocity Keep a minimum flow velocity to avoid sedimentations in the piping system Recommended velocities Vertical pipes 0 7 m s Horizontal pipes 1 0 m s 10 1 6 Installation depth The m...

Страница 41: ...2000 6 74H 3000 3000 3200 Pump type Net weight kg S3 110 300 2500 6 74H 3100 3100 3400 S3 110 300 3150 6 74H 3900 3900 4100 S3 120 300 2000 6 74M 3300 3200 3400 S3 120 300 2500 6 74M 3500 3300 3500 S3...

Страница 42: ...ST4 135 1400 2000 10 78E 4200 ST4 135 1400 2500 10 78E 4400 ST4 135 1400 3150 10 78E 4900 ST4 135 1400 1300 12 78E 4100 ST4 135 1400 1600 12 78E 4300 ST4 155 1600 2500 10 78F 4700 ST4 155 1600 3150 10...

Страница 43: ...iente declaraci n cumplen lo establecido por las siguientes Directivas del Consejo sobre la aproximaci n de las legislaciones de los Estados miembros de la CE UE FI EY EU vaatimustenmukaisuusvakuutus...

Страница 44: ...emo pod punom vlastitom odgovorno u da je proizvod S 72 74 78 na koji se odnosi deklaracija ispod u skladu sa dole prikazanim direktivama Saveta za uskla ivanje zakona dr ava lanica EC EU RU Grundfos...

Страница 45: ...d under reference number PR451461 For further information see below Range Certificate No Standards used Fr 72 Baseefa 07ATEX010 2X EN IEC 60079 0 2018 EN 60079 1 2014 EN ISO 80079 36 2016 EN ISO 80079...

Страница 46: ...3 or T4 Gb For Fr 74 78 Ex II 2G Ex db II B T3 or T4 Gb and equipped with the separate UKEX approval plate and UK type examination certificate For Fr 74 78 the Ex h IIB T4 Gb marked approval is based...

Страница 47: ...normes et sp cifications marocaines pour lesquelles la conformit est d clar e comme indiqu ci dessous Valable pour les produits Grundfos S 72 74 78 S curit des produits et services loi n 24 09 2011 et...

Страница 48: ...17 Technical Regulations on Use of Certain Hazardous Substances in Electrical and Electronic Equipment Standards used EN IEC 63000 2020 Resolution No 1055 2016 Technical regulation of the equipment an...

Страница 49: ...6 2017 EN ISO 80079 37 2017 ATEX S 72 Ex ATEX Baseefa07ATEX0102X ATEX SGS Fimko Oy No 0598 Helsinki Finland 103 03026 380 44 237 0400 ukraine grundfos com Grundfos Sz kesfeh rv r 1st of February 2022...

Страница 50: ...ical Regulations on Use of Certain Hazardous Substances in Electrical and Electronic Equipment Standards used EN IEC 63000 2020 Resolution No 1055 2016 Technical regulation of the equipment and the pr...

Страница 51: ...6 2017 EN ISO 80079 37 2017 ATEX S 74 78 Ex ATEX FM18ATEX0024X ATEX FM Approvals Europe Limited No 2809 Dublin Ireland 103 03026 380 44 237 0400 ukraine grundfos com Grundfos Sz kesfeh rv r 1st of Feb...

Страница 52: ...3 S ST 72 74 78 004 2011 010 2011 020 2011 012 2011 KAZ S ST 72 74 78 1 2 3 S ST 72 74 78 004 2011 010 2011 020 2011 012 2011 KG S ST 72 74 78 1 2 3 S ST 72 74 78 004 2011 010 2011 020 2011 012 2011 A...

Страница 53: ...1 2 3 S ST 72 74 78 004 2011 010 2011 020 2011 012 2011 http net grundfos com qr i 98765568 10000121035 1216 ECM 1200100 1110 Operating manual EAC...

Страница 54: ...85 716 111 Denmark GRUNDFOS DK A S Martin Bachs Vej 3 DK 8850 Bjerringbro Tel 45 87 50 50 50 Fax 45 87 50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterbur...

Страница 55: ...Singapore Pte Ltd 25 Jalan Tukang Singapore 619264 Tel 65 6681 9688 Faxax 65 6681 9689 Slovakia GRUNDFOS s r o Prievozsk 4D 821 09 BRATISLAVA Tel 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUB...

Страница 56: ...demarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2022 Grundfos...

Отзывы: