TM032018
Auto-coupling base unit installation on a plinth
The minimum required plinth heights (A) for
installation on auto coupling are indicated in the
following table.
Pump type
Minimum plinth
height (A) [mm]
Range 72
S2.90.250.xxxx.x.x
375
S2.100.250.xxxx.x.x
375
S2.100.300.xxxx.x.x
400
S3.110.300.xxxx.x.x
400
S3.120.500.xxxx.x.x
425
S3.135.500.xxxx.x.x
425
S3.140.600.xxxx.x.x
425
Range 74
S2.90.xx.xxx.xxxx.x.x
400
S2.100.xxx.xxx.xxxx.x.x
400
S3.110.xxx.xxx.xxxx.x.x
400
S3.120.xxx.xxx.xxxx.x.x
425
S3.135.xxx.xxx.xxxx.x.x
425
Range 78
Pressure class E, L, M, H
425
Pressure class F
0
Required tilt angle when the pump is lowered onto the
auto coupling: ± 5°.
TM033067
Lowering the pump onto an auto coupling
Submerged installation on auto coupling
Pumps for permanent installation can be installed on
a stationary auto coupling and operated completely or
partially submerged in the pumped liquid.
Before installing the auto-coupling base unit, ensure
the quality and strength of the concrete foundation.
See the pull-out strengths required for anchor bolts at
the end of this section. To ensure adequate pull-out
strength, weld the threaded bushings to the steel
reinforcement in the concrete.
For auto-coupling installations, types S
and C, the guide claw is mounted on the
outlet flange from the factory.