8. Fault finding chart

8.1 Emergency operation

In case of damage to electronic components belonging to the 
printed circuit board, the system can be operated by moving the 
multiplug from J2 to J4, see fig. 10.
Pumps will still operate automatically by pressure switches but 
without LED indications and the alternation function.

Maximum pressure and dry-running protection are not active 
when the booster set is in emergency operation.

Fig. 10

Before making any connections in pumps, terminal boxes or control box, the electricity supply must be switched off.

Fault

Cause

Remedy

1.

Motor does not run 
when started.

a) Electricity supply disconnected.

Connect the electricity supply.

b) Automatic circuit breakers cut out.

Correct the fault and cut in the automatic circuit break-
ers.

c) Fuse in the CS 1000 defective.

Replace the fuse.

d) Motor defective.

Repair/replace the motor.

2.

Motor starts, but stops 
immediately after-
wards. 

a) Incorrect setting of pressure switch.

Increase the cut-out pressure and/or differential 
pressure.

b) Wrong diaphragm tank precharge pressure.

Check the diaphragm tank precharge pressure.

3.

Frequent starts and 
stops.

a) Incorrect setting of time delay TR 2.

Set the time delay TR 2 accordingly.

b) Incorrect setting of pressure switch.

Increase the cut-out pressure and/or differential 
pressure.

c) Diaphragm tank defective.

Repair the diaphragm tank.

4.

Pumps are running but 
deliver no water.

a) Suction pipe/pumps blocked by impurities.

Clean the suction pipe/pumps.

b) Non-return valve blocked in closed position.

Clean the non-return valve.

c) Suction pipe leaky.

Repair the suction pipe.

d) Air in suction pipe/pumps.

Vent the pumps. Check the suction pipe for leakages.

e) Motors running with the wrong direction of rota-

tion.

Change the direction of rotation.

5.

Leakage from the shaft 
seal.

a) Shaft seal defective.

Replace the shaft seal.

b) Height adjustment of the pump shaft inaccurate.

Readjust the shaft height. See installation and oper-
ating instructions for CR pumps.

6.

Noise.

a) The pumps are cavitating.

Clean the suction pipe/pumps and possibly the suc-
tion strainer.

b) The pumps do not rotate freely (frictional

resistance) due to inaccurate height adjust-
ment of the pump shaft.

Readjust the shaft height. See installation and oper-
ating instructions for CR pumps.

TM

0

0

 9

742

 0

397

J2

J4

J2

J4

Содержание Hydro 1000

Страница 1: ...Hydro 1000 Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...tives on the approximation of the laws of the EC Member States relating to Machinery 98 37 EC Standard used EN ISO 12100 Electromagnetic compatibility 89 336 EEC Standards used EN 61 000 6 2 and EN 61...

Страница 3: ...rks blocks of flats hotels industry hospitals schools etc 1 2 Operating conditions Liquid temperature Maximum 50 C Ambient temperature 0 C to 40 C Operating pressure Maximum 10 bar Minimum and maximum...

Страница 4: ...s connected Dry running alarm The red indicator light is on when the dry running alarm is activated The light goes out when the alarm is reset If automatic resetting is chosen the indica tor light goe...

Страница 5: ...en the inlet pressure level drops below the set value the pumps are cut out When the correct pressure level value is restored the pumps can be reset to operation auto matically or manually 4 5 Priming...

Страница 6: ...6 Note A pilot pump is the pump that starts first stops last is generally smaller than the other pumps smaller flow higher head is not to be alternated must be installed in position P1 Before changin...

Страница 7: ...more pumps will be cut in until the performance of the pumps in operation cor responds to the requirements When the water consumption falls the discharge pressure rises to the cut out pressure and th...

Страница 8: ...8 Pump 1 will now start 9 Check the direction of rotation of the pump In case of incor rect rotation interchange two phases of the electricity supply 10 Vent the pump while slowly opening its discharg...

Страница 9: ...e pressure Check the diaphragm tank precharge pressure 3 Frequent starts and stops a Incorrect setting of time delay TR 2 Set the time delay TR 2 accordingly b Incorrect setting of pressure switch Inc...

Страница 10: ...a Supply Voltage 3 x 400 V 6 10 50 Hz PE Pos Description Number 1 Suction manifold 1 2 Discharge manifold 1 3 Base frame 1 4 Stand 1 5 Control box 1 6 CR pump 2 4 7 Non return valve 1 per pump 8 Isola...

Страница 11: ...Sasso 4 I 20060 Truccazzano Milano Tel 39 02 95838112 Telefax 39 02 95309290 95838461 Japan GRUNDFOS Pumps K K 1 2 3 Shin Miyakoda Hamamatsu City Shizuoka pref 431 21 Phone 81 53 428 4760 Telefax 81...

Страница 12: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96413144 0405 GB Repl 96413144 0902...

Отзывы: