12. Grundfos alarm and warning codes
This is a complete list of alarm and warning codes for Grundfos products. For the codes supported by this product, see the alarms and
warnings section.
Code
Description
Code
Description
Code
Description
1
Leakage current
36
Outlet valve
leakage
71
Motor temperature 2 (Pt100,
t_mo2)
2
Missing phase
37
Inlet valve leakage
72
Hardware fault, type 1
3
External fault signal
38
Vent valve defective
73
Hardware shutdown (HSD)
4
Too many restarts
39
Valve stuck or defective
74
Internal supply voltage too high
5
Regenerative braking
40
Undervoltage
75
Internal supply voltage too low
6
Mains fault
41
Undervoltage transient
76
Internal communication fault
7
Too many hardware shutdowns
42
Cut-in fault (dV/dt)
77
Communication fault, twin-head
pump
8
PWM switching frequency reduced 43
-
78
Fault, speed plug
9
Phase sequence reversal
44
-
79
Functional fault, add-on module
10
Communication fault, pump
45
Voltage asymmetry
80
Hardware fault, type 2
11
Water-in-oil fault (motor oil)
46
-
81
Verification error, data area (RAM)
12
Time for service (general service
information)
47
-
82
Verification error, code area (ROM,
FLASH)
13
Moisture alarm, analog
48
Overload
83
Verification error, FE parameter
area (EEPROM)
14
Electronic DC-link protection
activated (ERP)
49
Overcurrent (i_line, i_dc, i_mo)
84
Memory access error
15
Communication fault, main system
(SCADA)
50
Motor protection function, general
shutdown (MPF)
85
Verification error, BE parameter
area (EEPROM)
16
Other
51
Blocked motor or pump
86
Fault (add-on) I/O module
17
Performance requirement cannot
be met
52
Motor slip high
87
-
18
Commanded alarm standby (trip)
53
Stalled motor
88
Sensor fault
19
Diaphragm break (dosing pump)
54
Motor protection function, 3 sec.
limit
89
Signal fault, (feedback) sensor 1
20
Insulation resistance low
55
Motor current protection activated
(MCP)
90
Signal fault, speed sensor
21
Too many starts per hour
56
Underload
91
Signal fault, temperature sensor 1
22
Moisture switch alarm, digital
57
Dry running
92
Calibration fault, (feedback)
sensor
23
Smart trim gap alarm
58
Low flow
93
Signal fault, sensor 2
24
Vibration
59
No flow
94
Limit exceeded, sensor 1
25
Setup conflict
60
Low input power
95
Limit exceeded, sensor 2
26
Load continues even if the motor
has been switched off
61
-
96
Setpoint signal outside range
27
External motor protector activated
(for example MP 204)
62
-
97
Signal fault, setpoint input
28
Battery low
63
-
98
Signal fault, input for setpoint
influence
29
Turbine operation (impellers
forced backwards)
64
-
99
Signal fault, input for analog
setpoint
30
Change bearings (specific service
information)
65
Motor temperature 1 (t_m or t_mo
or t_mo1)
100
RTC time synchronisation with
GSM occured
31
Change varistor(s) (specific
service information)
66
Temperature, control electronics
(t_e)
101
-
32
Overvoltage
67
Temperature too high, internal
frequency converter module (t_m)
102
Dosing pump not ready
33
Soon time for service (general
service information)
68
External temperature or water
temperature (t_w)
103
Emergency stop
34
No priming water
69
Thermal relay 1 in motor, for
example Klixon
104
Software shutdown
35
Gas in pump head, deaerating
problem
70
Thermal relay 2 in motor, for
example thermistor
105
Electronic rectifier protection
activated (ERP)
Pumpland.ru