![Groen groen TDBCCE Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/groen/groen-tdbcce-series/groen-tdbcce-series_operators-manual_2268385008.webp)
8 OM-TDB/TDBC-CE
Initial Start-Up
Now that the kettle has been installed, you should test it to ensure that the unit is
operating correctly.
1. Remove all literature and packing materials from inside and outside of the unit.
2. Confirm that the kettle tilts properly. Either turn the crank or use the handle to tilt
the kettle and return it to the upright position.
3. Turn on the electrical service to the unit by setting the power switch to the ON
position. The green POWER indicator lamp should light.
4. Pour two to four liters of water into the kettle.
5. Following “To Start Kettle” instructions in the “Operation” section of this manual,
begin heating the water at the highest thermostat setting. The HEAT (amber)
indicator light should come on immediately, and heating should continue until
the water boils. The HEAT indicator will cycle on and off as the heater elements
are cycled under control of the thermostat.
6. To shut down the unit, turn the thermostat dial to “O” and the power switch to
OFF.
If the unit functions as described above, it is ready for use. If the unit does not function
as intended, contact your local Groen Certified Service Agency.
A simple turn of the thermostat controls the TDB
and TDBC kettle.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE. DIRECT
CONTACT COULD RESULT IN SEVERE BURNS.
IMPORTANT
BE SURE ALL OPERATORS READ,
UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS AND SAFETY
INSTRUCTIONS CONTAINED IN THIS
MANUAL.