22 OM-TDB/TDBC-CE

Electrical Parts List

400/230V with Neutral & 240V without Neutral

Key

Description

Part #

1

ASM, ELECTRICAL MOUNT-
ING BRACKET

148981

2

WATER LEVEL CONTROL 
BOARD

148323

3

MICRO SWITCH, 15 AMP 
125/250 VAC

002982

4

TERMINAL BLOCK 4 POLE 
85 AMP #14-4

088214

5

CONTACTOR 50 AMP RES 4 
POLE

119811

6

FUSE HOLDER TYPE 3 AG

077854

7

FUSE 3.0 AMP TYPE 3 AG

077853

8

PC BOARD MOUNTING POST

099901

9

SCREW #8-32 X 1-1/4" 
ROUND HD

005056

10

SCREW #4-40 X 3/4" 
ROUND HD

003122

11

BARRIER INSULATION

003490

12

WASHER SHAKEPROOF 
LOCK #6

005715

13

NUT HEX #4-40

003121

14

TRANSFORMER, 50VA 
208/230 V PRI, 24 V SEC

148899

15

LUG GROUND #14 - #6 AWG

129714

16

SCREW #8-32 X 3/8" HEX 
HD CAP

069789

17

SCREW #6-40 X 3/8" 
ROUND HD

009697

18

WIRING HARNESS ASM, 
TDB(C) 24 V CONTROL*

141364

19

WIRING HARNESS ASM, 
TDB(C) HIGH VOLTAGE WYE*

171819

20

WIRING HARNESS ASM, 
TDB(C) HIGH VOLTAGE DELTA*

162877

21

WIRING HARNESS ASM, TDB(C) 
HEATERS, 230/400 WYE*

141366

22

WIRING HARNESS ASM, 
TDB(C) HEATERS, 240 DELTA*

162876

23

SWITCH, TOGGLE*

122004

24

LIGHT, INDICATOR, GREEN, 24V* 162846

25

LIGHT, INDICATOR, AMBER, 24V*

116384

26

LIGHT, INDICATOR, RED, 24V*

116383

*Item not depicted/called out in drawing or photographs

Содержание groen TDBCCE Series

Страница 1: ...tions thoroughly before installing or servicing this equipment NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine...

Страница 2: ...THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER BEFORE ATTEMPTING ANY SERVICING ENSURE THAT THE ELECTRICAL SUPPLY IS DISCONNECTED WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO...

Страница 3: ...EPLACING ANY PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY WARNING KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND ELECTRICAL EQUIPMENT NEVER SPRAY OR HOSE THE SUPPORT HOUSING OR ELECTRICAL CO...

Страница 4: ...Parts Lists page 19 22 Wiring Diagram page 23 25 Service Log page 26 27 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOC...

Страница 5: ...e switch as safety features A heating indicator light pressure gauge and sight glass are provided for monitoring kettle operation A single electrical connection is required for installation The unit m...

Страница 6: ...ion for future reference Space for these entries is provided at the top of the Service Log at the back of this manual Keep this manual on file and available for operators to use When installation is t...

Страница 7: ...the incoming lines A BX connection is not recommended Observe all local and national codes and all regulations in force at the time of installation 5 Confirm that the jacket water level is above mid p...

Страница 8: ...at setting The HEAT amber indicator light should come on immediately and heating should continue until the water boils The HEAT indicator will cycle on and off as the heater elements are cycled under...

Страница 9: ...ank tilt turn the handle The kettle will remain in the position to which tilted until cranked again COMMON ACCESSORIES 1 Lift Off Cover As with stock pot cooking an optional lift off cover can speed u...

Страница 10: ...water to fully drain from product before moving basket away from the kettle Do not rest kettle basket on kettle rim or pouring lip If basket is too heavy for individual to lift and safely move get he...

Страница 11: ...nt the thermostat switch closes the HEAT indicator light comes on the contactors close and the heaters come on again On off cycling continues keeping the kettle at the set temperature This is why the...

Страница 12: ...housing Remove the access panels from the support housing with a screwdriver to gain access to the grease fittings Use a lithium based multi purpose grease When the access panels are removed the mount...

Страница 13: ...tle jacket 4 Water Treatment Procedure a Obtain water treatment compound and a PH test kit from your authorized Groen parts distributor b Fill the mixing container with the measured amount of water re...

Страница 14: ...le continues heating after it reaches the desired temperature User a Thermostat dial setting Authorized Service Rep Only b Thermostat circuit for short X c Thermostat operation The thermostat should c...

Страница 15: ...t purchased has been handcrafted from the finest materials meticulously inspected and carefully tested to ensure that you receive the best possible product With reasonable care and periodic maintenanc...

Страница 16: ...Kettle Prior to operation thoroughly clean the kettle using hot water and detergent Kettle capacities Model Maximum Capacity Recommended Capacity TDB C 20 18 9 liters 16 liters TDB C 24 22 6 liters 1...

Страница 17: ...h limit control will open and shut off power to the elements until the kettle cools Setting the operating thermostat dial to O shuts down the heating circuits Setting the power switch to the OFF posit...

Страница 18: ...plies 200 parts per million available chlorine Obtain advice on sanitizing agents from your supplier of sanitizing products Following the supplier s instructions apply the agent after the unit has bee...

Страница 19: ...ING 1 500 124764 20 WASHER LOCK 3 8 005618 21 SCREW 3 8 16 X 1 HEX HEAD 005612 22 WASHER FLAT 3 8 005830 23 WELDMENT KETTLE BODY 230 240V 20 QT 141353 23 WELDMENT KETTLE BODY 230 240V 40 QT 141355 33...

Страница 20: ...096963 2 THERMOSTAT 012313 3 WATER LEVEL ELECTRODE 015589 4 BRACKET 137736 5 COVER 003141 6 GASKET BOTTOM COVER 137969 7 SCREW 20 X 1 012597 8 GASKET BOTTOM COVER SCREW 137968 9 HEATER JUMPER WIRE 171...

Страница 21: ...Description Part 1 GAUGE COMPOUND PRESSURE W DUAL 084208 2 VALVE PRESSURE RELIEF 50 PSI 1 2 NPT PED 141360 3 ASSY WATER FILL SUB 137438 4 ELBOW 3 4 NPT 90 DEG STREET BRASS 010668 Item not depicted cal...

Страница 22: ...ER INSULATION 003490 12 WASHER SHAKEPROOF LOCK 6 005715 13 NUT HEX 4 40 003121 14 TRANSFORMER 50VA 208 230 V PRI 24 V SEC 148899 15 LUG GROUND 14 6 AWG 129714 16 SCREW 8 32 X 3 8 HEX HD CAP 069789 17...

Страница 23: ...OM TDB TDBC CE 23 Wiring Diagram 400 230 V with Neutral Wye...

Страница 24: ...24 OM TDB TDBC CE Wiring Diagram 240V 3 Phase without Neutral Delta...

Страница 25: ...OM TDB TDBC CE 25 Wiring Diagram 240V 1 Phase without Neutral Delta...

Страница 26: ...26 OM TDB TDBC CE Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Отзывы: