OM-TDB/TDBC-CE 7
The Groen Kettle is provided with complete internal wiring. It is ready for immediate
connection. A wiring diagram is provided in this manual and on the inside of the
control housing service panel. Any mechanical or electrical changes must be approved
by Groen’s Food Service Engineering Department.
The completed unit has been operated at the factory to test all controls and heater
elements.
1. Set the kettle in place and level it. The base should be securely fastened to a
table or work surface. Four 3/8”-16 N.C. threaded couplings are provided in the
base of unit. Installation under a ventilation hood is recommended.
2. Provide electrical power as specified on the electrical information plate attached
to the equipment. Observe all local and national codes, and all regulations in
force at the time of installation.
3. The equipment is shipped ready for three phase operation. Refer to the wiring
diagram for single phase operation.
4. Bring the electrical service through the entrance at the rear of the support
housing, making a watertight connection with the incoming lines. (A BX
connection is not recommended.) Observe all local and national codes, and all
regulations in force at the time of installation.
5. Confirm that the jacket water level is above mid point of sight glass. If the level
is low, follow the instructions under “Jacket Filling and Water Treatment,” Page
13.
6. Electrically earth the unit at the terminal provided.
7. Equipotential terminal: In accordance with national regulations, the unit has been
fitted with an equipotential terminal.
TDB(C) ELECTRICAL SPECIFICATIONS
KETTLE CHARACTERISTICS
VOLTAGE-FREQ-PHASE
TDB(C)-20, -24
TDB(C)-40, -48
230 V, 50/60 Hz,
1-Phase
33 Amps
57 Amps
240 V, 50/60 Hz,
3-Phase
20 Amps
40 Amps
400 V, 50/60 Hz,
3-Phase W/Neutral
33 Amps
57 Amps
ELECTRICAL SUPPLY CONNECTION REQUIREMENTS
KETTLE CHARACTERISTICS
20/24 QUARTS
19/23 LITERS
40/48 QUARTS
38/45 LITERS
VOLTAGE
PHASE
NEUTRAL
KW
AMPS
KW
AMPS
230
1
YES
7.8
33
13.3
57
240
3
NO
8.4
20
14.4
35
400
3 N
YES
7.8
11.2
13.3
19
WARNING
INSTALLATION OF THE KETTLE MUST
BE DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY. IMPROPER
INSTALLATION CAN RESULT IN INJURY
TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT.
DANGER
ELECTRICALLY GROUND THE UNIT AT
THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.
Installation