9
Connecting power (if fitted with a plug and lead proceed to next page)
It is recommended that 1.5mm
2
(max.) wire size is used to avoid unnecessary crowding and difficulty when making connec-
tions. Avoid lengthy cable ends that may cause undue pressure on delicate components. It is recommended to crimp cable
ends with fork or loop connectors to ensure a secure fitting in the terminal block.
Note:
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified per-
son in order to avoid a hazard
A disconnection device incorporated in the fixed wiring must be provided in accordance with the wiring rules of the
country in which it is installed.
Supply connection for three phase builds with neutral
Models: ML5053, ML5103, MH5103 & ML5153
Supply connection for single phase builds 3
wire configuration
Model: ML5051
Supply connection for single phase builds 4
wire configuration
Models: ML5102 & MH5102
ELECTRICAL CONNECTION
The
2.0
opener
must
:
be connected via an approved electrical isolation device
be connected via a suitable circuit breaker that disconnects all live conductors
be connected in accordance with the wiring rules of the country in which it is installed
not have control enclosures left open for extended periods (excess dust will void warranty)
Supply connection for three phase builds
without
neutral
Models: ML5053N, ML5103N, MH5103N &
ML5153N
A
.
3 PHASE
WITH
NEUTRAL
C
.
SINGLE PHASE 3 WIRE
D
.
SINGLE PHASE 4 WIRE