16
Example of a Typical Car Park Application
The 2.0 has Car Park Access Control features included as standard.
For typical vehicular access applications, the product can be interfaced with access control devices and features an adjustable
Auto Close function.
For vehicular access applications an Entrapment Protection System will be required — see “Installing Entrapment Protection De-
vices” on page 15.
Typical Car Park Configuration
The opener must be installed in accordance with the instructions contained within this document.
The Entrapment Protection Device/s must be installed before the product can be set for Auto Close.
For Latch Up (open) and Latch Down (close) set the dip switches on the MCB in accordance with the “Setting Door Behaviour”
instructions (see page 14)
Set Auto Close in accordance with the instructions (see page 19).
Access Control Options
Grifco® Se2.0 Transmitter or other Grifco® Se2.0 Wireless Accessories
Swipe Card, Magnetic Key or similar access control device
The transmitter once programmed (see page 20) can control entry and exit for the user. Auto Close once set, will close the door
after the programmed delay on both entry and exit.
Access control devices such as swipe card, magnetic key and other similar systems must be a two wire voltage free interface and
be connected to the toggle input on the MCB via the quick connect pluggable terminal block (see diagram on page 17).
Transmitter Management
If transmitter management is required, you will need a Grifco® STAR1000EVO. This accessory will allow up to 1000 identified users
to be individually added and deleted. Contact 1800 GRIFCO® for more information.
Exit Control
The door can be configured to open from either a:
Grifco® S2.0 Transmitter or other Grifco® S2.0 Wireless Accessory device, or
Where a loop detector or similar access controls are required to trigger opening to exit, connect to the toggle input on the
MCB via a quick connect pluggable terminal block as described above (see diagram page 17).
Note – The Toggle Input will accept N/O inputs from multiple access control devices eg, both a separate entry and exit control.
Auto Close Feature
When Auto Close is enabled, the Toggle Input, and Receiver behaviour will become “Open Only” i.e. an activation via the Toggle
Input or a Transmitter during opening, or Auto Close delay, will not close the door. Each activation will add Auto Close delay.
Advanced Logic Functionality
For applications where full logic functionality (eg relay status outputs, advanced door behaviour, building management system
integration) is required please order the Grifco® EB1, Elite Expansion Board or complete Elite Expansion Kit. Contact 1800 GRIFCO®
for more information.
WARNING
Keep additional accessories away from children. Do not allow children to play with pushbuttons or remote controls. Without
safety devices a door can cause serious injuries as it closes. Only trained people are allowed to use the opener.