Door behaviour modes
Latch up / Inch down mode (default):
The door will travel upwards with only a single press and release of the UP button. The door will stop at the set limit. This mode
is
latch up
.
The door will only travel downwards when the DOWN button is held. The door will stop at the closed limit or when the button is
released. This mode is
inch down
.
Inch up / Inch down mode:
The door will only travel whilst the UP or DOWN buttons are being held. The door will stop at the limits or when the button is
released. To set this mode refer to
Setting door behavior
information below.
Latch up and down mode:
Note:
This mode is only possible in conjunction with an Entrapment Protection Device such as an Infrared (IR) Beam or a
Safety Bump Edge. Failure to do so may result in damage to property or injury to persons.
Setting door behaviour
To set the door behaviour modes, adjust the DIP switches in the corner of the MCB shown below.
Dip switch
1
is used to latch
DOWN
and switch
2
is used to latch
UP
.
At default the MCB is set to latch open and inch close, shown right. The door will open with a
single press but only travel downwards while the down button is being held. For details on
the 3 distinct modes refer above.
* The door must only be set to latch DOWN if there is a suitable Entrapment Protection
Device installed. Failure to do so can lead to serious injury or death.
Note: **Both dips must be OFF (inch up/inch down) for Coles & BI-LO electrically operated roller door installations or when
opener height is less than 2.5m from the ground without sufficient guarding of moving parts.
WARNING
Entrapment Protection
The Entrapment Protection System for your installation will be determined by the functional requirements of the door. To ensure
the installation meets these requirements refer to AS/NZS 60335-2-103.
When using the Grifco® Protector System as part of the Entrapment Protection System, ensure it is installed to detect a 100mm
high obstacle, ie; approx 80mm from the floor, and in accordance with installation directions supplied.
Consideration should be given to the detection of vehicles or other similar equipment. To provide adequate Entrapment Protec-
tion an additional Grifco® Protector System may be required to be installed in a higher suitable position, for example, approx
600mm from the ground.
Latch up / inch down
*Latch up / latch down
**Inch up / inch down
ON
(LATCH)
OFF
(INCH)
DOOR BEHAVIOUR AND ENTRAPMENT PROTECTION INPUTS