7
Mounting the unit (continued)
Side room to imposing structures (see left).
The 2.0
APE housing is not a serviceable area and can be
located within 10mm of an imposing structure without affecting in-
stallation. Where there is insufficient side room, consider using the
opposite hand opener and mount inboard with a Grifco® Inboard
Mounting Kit, P/N IBMK
.
Limited head room (see right).
The 2.0 main control housing is a serviceable area and will
need to be accessed by service personnel. Refer below for options
on how to overcome problems in which sufficient head room is
not available.
If there is insufficient head room above the 2.0
opener to allow servicing then a Grifco® Wall Mount Kit
(P/N WMK2) or Grifco® Rotation Bracket (P/N RBK2)
can be used to reposition the main control housing.
Please contact your local dealer or Chamberlain for
more information.
Location of Controller (see left).
Controller has 6 metres of cable with RJ45 ends ready
to connect the 2.0 opener to the controller.
2.0 Controller Extension Kit (P/N ESK01) is
available if needed.
WARNING
When Securing the
eDrive +2.0
opener with the 4 x M12 x
40mm
long fasteners (based on a 8mm mounting plate) and spring
washers provided, it is critical to ensure that the applied torque is between 80-90Nm. When mounting through thicker sections,
ensure a minimum of 30mm of screw thread is engaged with the female thread. Use of incorrect fasteners or torque may cause
serious product damage, personal injury or death. When fixing through a slotted plate, ensure that the slots are no wider than
13mm as a spring washer may not be adequate in outside diameter to support the hexagon head.
6
5
150mm
Minimum
4
10mm Minimum
4