background image

Page | 1 

P

  800.872.3267   

F

  800.232.7329 

E

  [email protected] 

www.adamsrite.com 

EX89 Pullman Rim Exit Device 

Preparation Guide and Installation Instructions 

Box Contents 

EX89 Pullman Rim Exit Device 

Cylinder and Trim Interface Kit 

Mounting Hardware Kit 

Frame Kit with Templates 

Mounting End Cap Kit 

Recommended Installation Tools

 

Safety glasses 

 Measuring tape    

 Level   

  Pencil 

Power drill

    Drill bits: 5/32”, 3/4”  

 Center punch 

 Phillips screw driver 

IMPORTANT NOTE 1:  All work must be performed to applicable building, regulatory and life-
safety codes.  Please consult local Authority Having Jurisdiction (AHJ) for more information.
 

IMPORTANT NOTE 2:  The Americans with Disabilities Act (ADA) guidelines specify door 
hardware be mounted 34”-48” above the finished floor. 

Active Push Bar 

Filler Plate 

Back Bar 

Содержание Adams Rite EX89

Страница 1: ...g End Cap Kit Recommended Installation Tools Safety glasses Measuring tape Level Pencil Power drill Drill bits 5 32 3 4 Center punch Phillips screw driver IMPORTANT NOTE 1 All work must be performed to applicable building regulatory and life safety codes Please consult local Authority Having Jurisdiction AHJ for more information IMPORTANT NOTE 2 The Americans with Disabilities Act ADA guidelines s...

Страница 2: ...eparation using dimension A as shown in the chart below 5 IF standard door widths as shown in the chart below are not being used THEN CUT to proper length using Sizing the Exit Device chart on page 4 6 MARK CENTER PUNCH DRILL all holes 7 PREPARE door for cylinder and or trim using Preparing the Door for Cylinder or Trim on page 5 if required 8 REMOVE the templates Standard Door Widths and Mounting...

Страница 3: ...vice on the frame for the strike plate 2 DETERMINE the location of the strike plate template by using the bar height centerline of the exit device and aligning the template with the surface of the closed door 3 MARK CENTER PUNCH DRILL all holes 4 REMOVE the template 1 from inside surface of closed door Cut away stop Bar Height Centerline 1 1 2 3 1 2 Drill 5 32 dia pilot holes for self tapping scre...

Страница 4: ...m Door Width Exit Device Can Support 30 30 42 NOTE All EX Series Exit Devices are sized at the factory for 5 8 frame stop in narrow stile aluminum applications 1 DETERMINE cut off dimension B Back Bar extrusion length by subtracting 3 7 8 from door opening width 2 MARK cut off line B on Filler Plate and Back Bar 3 REMOVE Filler Plate from Back Bar and CUT along lines on both pieces REPLACE Filler ...

Страница 5: ...red 2 PREPARE the door for cylinder mounting or trim mounting according to manufacturer s instructions as required 3 16 Mounting Centerline Bar Height Centerline Cylinder Centerline Bar Height Centerline Bar Height Centerline 1 4 1 4 13 16 13 32 3 8 dia 7 32 dia thru c sink 3 8 dia x 82 deg 2 plc cylinder only Exterior Preparation for Use with Cylinder Interior Preparation for Use with Trim and Cy...

Страница 6: ...on with Cylinder or Trim NOTE The orientation of the trim plate differs for LHR and RHR applications The Trim Actuator is ALWAYS located on the bottom of the Trim Plate IF installing cylinder or trim THEN DETERMINE the door handing and INSTALL accompanying Cylinder and Trim Interface Kit Left Hand Reverse LHR Right Hand Reverse RHR ...

Страница 7: ...pplications Use provided wood screws for wood applications 1 INSTALL Mounting Foot on hinge side of door using two 2 10 32 x 3 4 pan head screws Leave screws slightly loosened for final adjustment 2 SLIDE the exit device onto the mounting foot 3 INSTALL Pullman Mounting Base on latch side of door using two 2 10 32 x 3 4 pan head screws Leave screws slightly loosened for final adjustment ...

Страница 8: ... 32 x 3 4 flat head screws 2 VERIFY that exit device is fully operational 3 ADJUST strike plate as necessary 4 MARK CENTER PUNCH DRILL 5 32 diameter pilot hole for center screw 5 INSTALL the 10 32 x 3 4 flat head self tapping center screw to maintain optimum adjustment 10 32 x 3 4 flat head self tapping screws 2 qty 10 32 x 3 4 flat head self tapping screw 1 qty ...

Страница 9: ...e Active Push Bar disables the latching function making the door a simple push pull operation 3 DEPRESS and HOLD active push bar in unlocked position 4 INSERT and ROTATE hex key one quarter turn clockwise to lock device DOG into position 5 ROTATE hex key one quarter turn counterclockwise to unlock device and release device into motion 6 ENSURE exit device is operational and ADJUST as required NOTE...

Страница 10: ...h side of door using two 2 8 32 x 3 8 tri lobe pan head screws Maintenance 1 CHECK mounting fasteners periodically and TIGHTEN if loose 2 APPLY screw locking compound or CHANGE part fasteners if screws continue to back out 3 PERFORM periodic and required checks and adjustments of strikes to compensate for wear and tear such as door sagging Warranty For complete warranty information please visit th...

Отзывы: