62
Index
Indication
Unit
0.
Frequency of electrical grid
Hz
1.
Voltage of electrical grid phase R
V
2.
Voltage of electrical grid phase S
V
3.
Voltage of electrical grid phase T
V
4.
Input voltage of DC tracker 1
V
5.
Input voltage of DC tracker 2
V
6.
Input voltage of DC tracker 3
V
7.
Input current of DC tracker 1
A
8.
Input current of DC tracker 2
A
9.
Input current of DC tracker 3
A
A.
Designated network communication address
E.
Cumulative power generated today (E-Today)
kWh
10.2.4 Error Messages
Error Message
Indication
KEEP PV OFF
Internal fault detected
Please keep DC breaker of solar panels off
C1
High DC current detected
C2
Relay failed
C3
DC current sensor failed
C4
Internal temperature of inverter high
C5
GFCI detection failed
C6
Bus Failed
C7
Anti-islanding detection (or AFD) failed
FAN FAILS
Fan not working properly