44
9.
Modbus Address: Designated address of inverter for all communication
purposes in the monitoring network.
10.
AC Nominal Frequency: GF: 59.5 ~ 60.3Hz; AC Voltage Range: GF: 198.0
~ 248.0V.
7.4.6 Error Frame
An error implicates abnormal activity of the solar system. The frame pops up
automatically after detection of an error. The second text line indicates error
type. Error types are defined in the table below.
Error
Implication
AC VOLT HIGH
Grid (AC) voltage is higher than preset
AC VOLT LOW
Grid (AC) voltage is lower than preset
AC FREQ HIGH
Grid frequency is higher than preset
AC FREQ LOW
Grid frequency is lower than preset
PV VOLT HIGH
PV voltage is higher than allowed
PV ISUL LOW
The insulation resistance between either PV (+) or
PV (-) to earth is lower than 2.0 MΩ
GFCI HIGH
Ground Fault Current is higher than specified