10.3.3 Error Mode
When inverter encounters an error, LCM screen enter error mode and an error
message will be displayed on LCM screen continuously.
AC VOLT HIGH
Vac 271V
This error message will remain on-screen until user presses the button on LED
panel to unlock and exit error mode. When exited, the LCM screen returns to
regular mode and goes to the information frame displaying the solar power
being generated at the moment (unit: W) and cumulative solar power that has
been generated today (unit: kWh). The error message mentioned above will be
recorded in Last ERROR information frame. Refer to the table below for
interpretation of all inverter error messages.
Error Message
Indication
AC VOLT HIGH
Vac XXX V
Grid voltage over range
Measured voltage displayed
AC VOLT LOW
Vac XXX V
Grid voltage below range
Measured voltage displayed
AC FREQ HIGH
fac XXX.X Hz
Grid frequency over range
Measured frequency displayed
AC FREQ LOW
fac XXX.X Hz
Grid frequency below range
Measured frequency displayed
PV VOLT HIGH
Vdc XXX V
Solar panel voltage over range
Measured voltage displayed
PV ISUL LOW
Check for insulation of solar panels failed
Ground I high
Ig XXX mA
Leakage current high
Measured current displayed
ARC FAULT
High-voltage arcing observed within inverter
Содержание PV-10000T-U
Страница 12: ...11 5 4 Product Labels ...
Страница 14: ...13 6 2 Unpacking PV 15000T U ...
Страница 15: ...14 6 3 1 Unpacking PV 20000T U ...
Страница 16: ...15 6 3 2 Unpacking PV 20000T U E Display ...
Страница 17: ...16 6 4 Assembly Chart PV 5000T U PV 8000T U PV 10000T U PV PV15000T U ...
Страница 18: ...17 6 5 Assembly Chart PV 20000T U ...
Страница 81: ...80 14 Addendum 14 1 Efficiency Charts 14 1 1 PV 5000T U 14 1 2 PV 8000T U ...
Страница 82: ...81 14 1 3 PV 10000T U 14 1 4 PV 15000T U ...
Страница 83: ...82 14 1 5 PV 20000T U ...
Страница 84: ...P N MUB0 A00000 0 ...