12. Troubleshooting
In cases where an inverter detects a problem, an error message may be
conveyed by the system. Use the table below to resolve accordingly. If the
problem persists, contact your local service provider for further assistance.
Trouble
Suggestions
No display or
incorrect display
1.
Check AC connection segments such as fuses,
breakers and wires. Be sure AC is connected
to inverter properly.
2.
Switch AC off and on again.
No generation
(No Error)
1.
Check PV wiring.
2.
Check PV polarities.
3.
Check PV voltages.
4.
Wait for stronger sunlight.
Error on display
Refer to error table in Error Frame section.
1.
Error other than “C#”: Check the error
message and take suitable action.
2.
“C#” Error: Switch off the AC breaker then
the DC breaker. Switch on the DC breaker
then the AC breaker again.
3.
If “C#” error persists, call your local service
provider for assistance.
Generated power
less than expected
1.
Check module installation.
2.
Ensure inverter is not in direct sun light.
3.
Remove all objects on inverter.
4.
Check inverter’s ambient temperature.
Содержание PV-10000T-U
Страница 12: ...11 5 4 Product Labels ...
Страница 14: ...13 6 2 Unpacking PV 15000T U ...
Страница 15: ...14 6 3 1 Unpacking PV 20000T U ...
Страница 16: ...15 6 3 2 Unpacking PV 20000T U E Display ...
Страница 17: ...16 6 4 Assembly Chart PV 5000T U PV 8000T U PV 10000T U PV PV15000T U ...
Страница 18: ...17 6 5 Assembly Chart PV 20000T U ...
Страница 81: ...80 14 Addendum 14 1 Efficiency Charts 14 1 1 PV 5000T U 14 1 2 PV 8000T U ...
Страница 82: ...81 14 1 3 PV 10000T U 14 1 4 PV 15000T U ...
Страница 83: ...82 14 1 5 PV 20000T U ...
Страница 84: ...P N MUB0 A00000 0 ...