background image

3

 

The vacuum pump is applicable to continuous operation (Pay attentions to 

precautions of oil circulation; see Oil Circulation in Page 3; see Oil return in 

Page 8). 
The vacuum pump is ultimate pressure proof. 

 

Principle of operation 

The vacuum pump works on the rotating vane principle. 

A circular rotor (14) is positioned centrically on the shaft of the vacuum 

pump. The shaft of the vacuum pump is driven by the drive motor shaft by 

means of a flexible coupling (310). 

The rotor (14) rotates in an also circular, fixed cylinder (1), the centerline of 

which is offset from the centreline of the rotor such that the rotor and the 

inner wall of the cylinder almost touch along a line. Vanes (22), sliding in 

slots in the rotor, separate the space between the rotor and the cylinder into 

chambers. At any time gas is sucked in and at almost any time ejected. 

Therefore the vacuum pump works almost pulsation free. 

In order to avoid the suction of solids, the vacuum pump is equipped with a 

mesh screen (261) in the suction connection. 

In order to avoid reverse rotation after switching off, the vacuum pump is 

equipped with a non-return valve (257) 

NOTE

: This valve shall not be used as a non-return valve or shut –off valve 

to the vacuum system and is no reliable means to prevent suction of oil into 

the vacuum system while the vacuum pump is shut down. 

In case the vacuum pump is equipped a gas ballast (optional): 

Through the gas ballast valve (440) a small amount of air is sucked into the 

pump chamber and compressed together with the process gas. This 

counteracts the accumulation of condensates from the process gas inside 

the vacuum pump (see “Conveying Condensable Steams” in Page 8). 

The gas ballast is designed with paper filter (Note: 1RV0020-1RV0040 gas 

ballasts are configured with sintered metal filters). 

Gas ballast version with ball valve: 

The gas ballast line can be closed partially or completely by means of a ball 

valve. 

In order to improve the operating characteristics the outlet of the pump 

chamber is equipped with a discharge valve (159). 

 

Oil Circulation 

The vacuum pump requires oil to seal the gaps, to lubricate the vanes (22) 

and to carry away compression heat. 

The oil reservoir is located on the pressure side of the vacuum pump (i.e. 

high pressure) at the bottom of the bottom chamber of the oil separator (75). 

The feed openings are located on the suction side of the vacuum pump (low 

pressure). 

Forced by the pressure difference between pressure side and suction side 

oil is being drawn from the oil separator (75) through the oil supply lines 

(210) and injected on the suction side. 

Together with the sucked gas the injected oil gets conveyed through the 

vacuum pump and ejected into the oil mist separator (75). Oil that separates 

before the exhaust filter (120) accumulates at the bottom of the bottom 

chamber of the oil separator (75). 

Oil that is separated by the exhaust filter (120) accumulates at the bottom of 

the upper chamber of the oil separator (75). 

The flow resistance of the exhaust filters (120) causes the inside of the 

exhaust filters (which is connected to be bottom chamber of the oil separator) 

to be on a higher pressure level than the outside of the exhaust filters (the 

upper chamber of the oil separator). Because of the higher pressure in the 

bottom chamber it is not possible to let oil that drips off the exhaust filters 

simply flow down to the bottom chamber. 

As the vacuum pump is equipped with float valve (200) and oil return pipe at 

the inlet: 

The oil accumulated in the upper chamber of the oil separator flows in the 

air inlet (250) through the float valve (200) and oil return pipe (195) 

As the vacuum pump is equipped with oil return valve (280): 

In continuous operating conditions, it is possible that the oil sucked into 

pump chamber accumulates at the bottom of the upper chamber of the oil 

separator, and then drains out along with the gas discharge/pressure, 

resulting in oil-free pump operation; therefore, turn off the vacuum pump 

and wait for at least 15 minutes for every 10 hours’ continuous operation. 

Depending on different working environments, the period of continuous 

operation may be even shortened (See Operation Notes in Page 8). After 

the vacuum pump is turned off, the pressure difference in and out of exhaust 

filter (120) is zero. The pressure in both chambers of oil separator is 

balanced. Open the oil return valve (280) between two chambers to drain 

the oil accumulated in the upper chamber of the oil separator by gravity into 

the bottom chamber.

 

 

Cooling 

The vacuum pump is cooled by

 

-the ambient air around the vacuum pump, including oil mist separator (75) 

-he air flow from the fan wheel (400) 

-the conveyed gas 

-he air flow from the fan wheels (321) on the shaft of the vacuum pump 

 

On/Off switch 

The vacuum pump comes without on/off switch. The control of the vacuum 

pump is to be provided in the course of installation. 

 

 

 

Safety 

Intended use 

DEFINITION

: For the purpose of these instructions, “handling” the vacuum 

pump means the transport, storage, installation, commissioning, influence 

Содержание 1RV0020

Страница 1: ...IilEEN O 1RV0160 11 RV0200 11 RV0250 11 RV0300 CE 1RV0020 1RV0025 1RV0040 1RV0063 1RV0100 Operating Instruction Rotary Vane Vacuum Pump Manufacturer Zhejiang Greenco Industry Co Ltd...

Страница 2: ...during operation 11 Assessment 11 Change of the exhaust filters 11 Overhaul 12 Removal from Service 12 Temporary Removal from Service 12 Recommissioning 12 Dismantling and Disposal 12 Troubleshooting...

Страница 3: ...d return oil pipe The vacuum pump is thermally suitable for continuous operation 100 output The vacuum pump is provided with oil return valve 280 Unit 1RV0020 1RV0025 1RV0040 1RV0063 1RV0100 Pumping r...

Страница 4: ...e pressure difference between pressure side and suction side oil is being drawn from the oil separator 75 through the oil supply lines 210 and injected on the suction side Together with the sucked gas...

Страница 5: ...ithout Packaging In case the vacuum pump is packed in the carton package lined with internal expanding lining Remove the lining out of the carton If the vacuum pump is lined with corrugated foil in th...

Страница 6: ...he given quantity in the tables below Oil Type Corex HLP D 68 P N 0831 512 575 or a conservation oil from same quality NOTE VCI stands for Volatile Corrosion Inhibitor VCI products film paper cardboar...

Страница 7: ...t to be used for this purpose If the vacuum pump is planned to be used for the suction of gas that contains limited quantities of condensable vapor Provide a shut off valve a drip leg and a drain valv...

Страница 8: ...rmine the intended direction of rotation with the arrow 431 Bump the drive motor 400 Watch the fan wheel of the drive motor 400 and determine the direction of rotation just before the fan wheel stops...

Страница 9: ...conditions Measure the drive motor current and record it as reference for future maintenance and troubleshooting work Version with exhaust filter pressure gauge Read the scale of the exhaust filter pr...

Страница 10: ...um pump cool down In case of oil draining let the vacuum pump cool down for no more than 20 minutes Prior to disconnecting connections make sure that the connected pipes lines are vented to atmospheri...

Страница 11: ...rmal conditions there should be no need to top up oil during the recommended oil change intervals A significant level drop indicates a malfunction see Troubleshooting in page 13 NOTE During operation...

Страница 12: ...Make sure the float valve 200 works normally and the vacuum pump generates limit pressure the prevent the oil from spilling out from discharge port 155 Make sure that the vacuum pump is shut down and...

Страница 13: ...drive motor draws too much current and or the pump flow rate has dropped then the exhaust filters 120 are clogged and must be replaced NOTE Exhaust filters cannot be cleaned successfully Clogged exha...

Страница 14: ...ful material can reside in pores gaps and internal spaces of the vacuum pump Danger to health during dismantling of the vacuum pump Danger to the environment During dismantling of the vacuum pump pers...

Страница 15: ...of damage to equipment Electrical installation work must only be executed by qualified personnel that knows and observes the following regulations IEC 364 or CENELEC HD 384 or DIN VDE 0100 respectivel...

Страница 16: ...losed or partially open position Disassemble the inlet valve clean the mesh screen 261 and the valve 257 as required and reassemble The oil tubing is defective or leaking The oil return pipe 195 is br...

Страница 17: ...r Top up oil Oil burnt from overheating Flush the vacuum pump Replace the oil filter 100 Replace the exhaust filters 120 Fill in new oil see Maintenance in page 8 In case the oil life is too short use...

Страница 18: ...eck the process Observe the chapter Installation and Commissioning Operating Notes Conveying Condensable vapors in page 8 The vacuum pump runs in the wrong direction in the case that it is equipped wi...

Страница 19: ...uck at opening Roll the float valve 200 or replace it when necessary Checking float valve in page 10 Oil return pipe 195 clogged or damaged Clean the clogged oil return pipe 195 replace the damaged oi...

Страница 20: ...19 1RV0020 Exploded drawing Exploded drawing...

Страница 21: ...20 1RV0025 0040 Exploded drawing Exploded drawing...

Страница 22: ...21 1RV0063 0100 Exploded drawing Exploded drawing...

Страница 23: ...Plug 1 89 O ring 1 95 Drain plug 1 96 O ring 1 99 Threaded joint 100 Oil filter 105 End cap of exhaust filter 106 Seal 107 Hex bolts 122 Exhaust filter with O rings 125 Exhaust filter springs 136 Sea...

Страница 24: ...filter 2 159 Discharge valve 2 185 Oil separator seal 1 186 Studs 4 Wearing parts kit Wearing parts kit Description Part No Maintenance kit Including oil filters exhaust filters and related sealing p...

Страница 25: ...justment range 1 6 2 4A 3Ph Motor safety switch Adjustment range 2 4 4 0A 3Ph Motor safety switch Adjustment range 4 0 6 0A 3Ph Motor safety switch Adjustment range 6 0 10 0A 3Ph Motor safety switch A...

Страница 26: ...thout authorization by GREENCO are also out of the guarantee scope The non proper application such as voltage high or low environment temperature will affect the performance and life therefore it will...

Страница 27: ...24 Zhejiang Greenco Industry Co Ltd Rongshi Road Danya Industrial Zone Zeguo Town Wenling Zhejiang 317523 China Tel 86 576 86428999 Fax 86 576 86409555 www greenco cn...

Отзывы: