Check after installation

Check after installation

• Check according to following after finishing installation.

Items to be checked

Possible malfunction

1. Preparation of test operation

•  The client approves the air conditioner.

•  Specify the important notes for air conditioner to the client.

2. Method of test operation

•  Put through the power, press ON/OFF button on the remote controller to start

operation.

•  Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check

whether the operation is normal or not.

•  If the ambient temperature is lower than 16°C , the air conditioner can't

start cooling.

Has the unit been installed solidly?
Have you done the refrigerant leakage

test?

Is heat insulation of pipeline sufficient?

Is water drained well?

Is the voltage of power supply 

according to the voltage marked on the

nameplate?
Is electric wiring and pipeline installed

correctly?
Is the unit grounded securely?
Does the power wire follow the 

specification?
Is there any obstruction in the air inlet

and outlet?
The dust and sundries caused during

installation are removed?
The gas valve and liquid valve of

connection pipe are open completely?

It may cause insufficient cooling

(heating) capacity.

It may cause malfunction or damaging

the parts.

It may cause insufficient cooling

(heating) capacity.

It may cause malfunction or damaging

the parts.

It may cause electric leakage.

It may cause malfunction or damaging

the parts.

It may cause malfunction or damaging

the parts.

It may cause condensation and water

dripping.

It may cause condensation and water

dripping.

It may cause insufficient cooling 

(heating) capacity.

The unit may drop, shake or emit noise.

Vérification après l'installation

À vérifier après l'installation

• F

aite

s le

s v

érif

ica

tio

ns 

sui

van

tes

 ap

rès

 av

oir 

com

plé

té 

l'in

sta

lla

tio

n.

Points à vérifier

Défectuosités possibles

L'ap

par

eil a

-t'il

 ét

é s

olid

em

ent

 in

sta

llé

 ?

Ave

z-v

ous

 vé

rifié

 s'i

l n

'y 

a p

as 

de 

fui

te 

?

Les

 tu

yau

x d

e l'a

ppa

rei

l s

ont

-ils

 bi

en

iso

lés

 ?

L'ea

u e

st-e

lle

 dr

ain

ée 

cor

rec

tem

ent

 ?

La 

ten

sion

 co

rre

spo

nd-

elle

 à 

la 

ten

sion

 

nom

ina

le 

qui 

figu

re 

sur

 la 

plaq

ue 

sign

alét

iqu

e?

Les

 fils

 él

ect

riq

ues

 et

 le

s tu

yau

x s

ont

-ils

rac

cor

dés

 co

rre

cte

men

t ?

L'ap

par

eil a

-t-i

l é

té 

mis 

à la

 te

rre

 

cor

rec

tem

ent

 ?

Le 

cor

don

 d’

alim

ent

atio

n e

st-i

l c

onf

orm

e

aux

 no

rm

es 

spé

cifé

es 

?

Est

-ce

 qu

e l'e

ntré

e o

u la

 so

rtie

 d'a

ir s

ont

obs

tru

ées

 ?

L'ap

par

eil a

-t-il

 été

 ne

ttoy

é et

 dé

bar

ras

sé d

e la

pou

ssiè

re e

t de

s dé

tritu

s fa

its 

dur

ant 

l'in

stal

lati

on ?

Les

 va

lve

s so

nt-e

lles

 co

mplè

tem

ent

 ou

ver

tes

?

1.A

van

t le

 te

st d

e fo

nct

ion

nem

ent

• V

érif

ier

 si 

le 

clie

nt e

st s

atis

fait

.  

• I

nfo

rm

ez l

e cl

ien

t su

r le

s p

oint

s im

por

tan

ts d

e l'a

ppa

reil

.

2.F

aire

 le

 te

st d

e fo

nct

ion

nem

ent

• M

ettr

e le

 co

ura

nt é

lec

triq

ue 

et  

app

uye

z su

r la

 to

uch

e 'O

N/O

FF'

 de

 la 

télé

com

man

de 

pou

r d

ém

arre

r l'a

ppa

reil

.

• A

ppu

yez

 su

r la

 to

uch

e 'M

ODE

' p

our

 ch

oisi

r A

UTO

, C

OO

L, D

RY,

 FA

N e

t H

EAT

 

et a

ins

i vé

rifie

r si

 l'a

ppa

reil

 fo

ncti

onn

e n

orm

alem

ent

 ou

 no

n.

• S

i la

 te

mpé

rat

ure

 am

bian

te 

est 

en 

bas

 de

 16

°C,

 le 

clim

atis

eur

 ne

 fo

ncti

onn

era

 pa

s.   

Cela

 pe

ut a

ffe

cte

r le

 re

nde

men

t d

l'ap

par

eil (

en 

clim

atis

atio

n o

u ch

auf

fag

e).

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er l

es 

piè

ces

.

Cela

 pe

ut a

ffe

cte

r le

 re

nde

men

t d

e la

 

clim

atis

atio

n o

u d

u ch

auf

fag

e.

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er d

es 

piè

ces

.

Cel

a p

eut

 en

tra

îne

r u

ne 

disp

ers

ion

 

éle

ctri

que

.

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er l

es 

piè

ces

.

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er l

es 

piè

ces

.

Cel

a p

eut

 fa

ire

 de

 la

 co

nde

nsa

tio

n o

u

l'ap

par

eil p

eut

 dé

gou

tte

r.

Cel

a p

eut

 fa

ire

 de

 la

 co

nde

nsa

tio

n o

u

l'ap

par

eil p

eut

 dé

gou

tte

r.

Une

 fu

ite

 ris

que

 d'a

ffe

cte

r le

 re

nde

men

t

de 

la 

clim

atis

atio

n o

u d

u c

hau

ffa

ge.

L'ap

par

eil p

eut

 to

mbe

r, v

ibr

er o

u ê

tre

 br

uya

nt.

00708_Owner's manual Lomo_Mise en page 1  15-03-03  14:51  Page38

Содержание LOMO 23 Series

Страница 1: ...our product Please read this owner s manual carefully before operating the unit and keep it for future reference GWC09QB D3DNA6E GWH09QB D3DNA6E GWC12QC D3DNA6E GWH12QC D3DNA6E GWC18QD D3DNA6E GWH18QD D3DNA6E GWC24QE D3DNA6E GWH24QE D3DNA6E ...

Страница 2: ......

Страница 3: ...equirements for electric connection 23 Installation Installation of indoor unit 24 Installation of outdoor unit 29 Vacuum pumping 32 Leakage detection 32 Check after installation 33 Test and operation Test operation 33 Attachment Configuration of connection pipe 34 Pipe expanding method 36 Wired Controller 37 This appliance is not intended for use by persons including children with reduced physica...

Страница 4: ......

Страница 5: ...e made by children Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard Do disconnect power supply when cleaning air conditioner Otherwise it may cause electric shock If the supply wire is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not wash the air conditioner with water to avoi...

Страница 6: ......

Страница 7: ...se it may cause malfunction An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Air Conditioner should be properly grounded Incorrect grounding may cause electric shock Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring may cause mal function of the unit elect...

Страница 8: ......

Страница 9: ... the fence around the outdoor unit for safety purpose The indoor unit should be installed close to the wall Instructions for installation and use of this product are provided by the manufacturer Working temperature range Indoor side DB WB C Outdoor side DB WB C Maximum cooling NOTICE The operating temperature range outdoor temperature for cooling only unit is 18 0 4 F 46 1 115 F for heat pump unit...

Страница 10: ......

Страница 11: ...LED color indicator Green status ON Red status OFF Mode LED color indicator White W Cool Mode Red R Heat Mode Green G Dry Mode drying indicator display Display and icons position may vary with models W R G W R O For some model receiver window display only for heating mode temp indicator Power LED color indicator Green status ON Red status OFF Mode LED color indicator White W Cool Mode Red R Heat M...

Страница 12: ......

Страница 13: ...eration mode In unit on status press MODE button to select operation mode in following sequence No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Button name ON OFF TURBO MODE I FEEL TEMP LIGHT X FAN SLEEP CLOCK TOFF TON FAN Function Turn on or turn off the unit Set turbo function Set operation mode Set up down swing status Set I FEEL function Switch temperature displaying type on the unit s display Set h...

Страница 14: ......

Страница 15: ...ion absorbing the dusts and killing the bacteria in the room 5 Setting turbo function 6 Setting light function 7 Viewing ambient temperature 8 Setting X FAN function In cool or dry mode press X FAN button to set X FAN function When is displayed X FAN function is on When you cancel the function by pressing again the button the icon will disappear When X FAN function is on after you have pressed the...

Страница 16: ......

Страница 17: ...he button and any operation on the button is invalid 2 Switching temperature scale In unit off status press MODE button and button simultaneously to switch temperature scale between and 3 Setting energy saving function In unit on status and under cool mode press CLOCK and TEMP buttons simultaneously to enter energy saving mode u When is displayed energy saving function is on u When is not displaye...

Страница 18: ......

Страница 19: ...ean the air conditioner Clean surface of indoor unit If the remote control is lost or damaged please use auxiliary button to turn on or turn off the air conditioner As shown in the figure open the panel press the auxiliary button to turn on or turn off the air conditioner When the air conditioner is turned on it will operate under auto mode When the surface of indoor unit is dirty it is recommende...

Страница 20: ......

Страница 21: ...any packing materials are recyclable Please dispose of them in appropriate recycling bin 2 If you want to get rid of the air conditioner please contact local dealer or recycling service center for the correct disposal method 1 Check that air inlets and air outlets are not blocked 2 Check if circuit breaker and connection are in good condition 3 Check that filters are clean 4 Check that drainage pi...

Страница 22: ......

Страница 23: ...per range Doors and windows are open Close doors and windows Adjust temperature to proper range Clean the filter Wait until the voltage resumes to normal Your required temperature exceeds the set temperature range Temperature can t be adjusted under auto mode Please switch the operation mode if you need to adjust temperature Set temperature range 15 C 3o C This is because indoor air is cooled rapi...

Страница 24: ......

Страница 25: ...lified professionals for service It can be eliminated after restarting the unit If not please contact qualified professionals for service It can be eliminated after restarting the unit If not please contact qualified professionals for service Please contact qualified professionals for service Please contact qualified professionals for service F2 Please contact qualified professionals for service W...

Страница 26: ......

Страница 27: ...e following places may cause malfunction If it is unavoidable please consult your local dealer or a certified technician 1 A place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 A place with high frequency devices such as welding machine medical equipment 3 A place near coast area 4 A place with oil or fumes in the air 5 A place with sulphurous g...

Страница 28: ......

Страница 29: ...nt out the screw fixing holes on the wall 2 Drill the screw fixing holes on the wall with the impact drill the specifica tion of drill head should be the same as the plastic expansion particle and then fill the plastic expansion particles in the holes 3 Fix the wall mounting frame on the wall with tapping screws ST4 2X25TA and then check if the frame is firmly installed by pulling the frame If the...

Страница 30: ......

Страница 31: ...ind the joint with tape 1 Open the panel remove the screw on the wiring cover and then take down the cover Note Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided 30 40 4 open end wrench union nut pipe torque wrench indoor pipe outlet pipe drain hose tape outlet pipe drain hose drain hose insulating pipe panel screw wiring...

Страница 32: ......

Страница 33: ... pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and close to the wall 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end connection pipe indoor units gas pipe indoor and outdoor pow...

Страница 34: ......

Страница 35: ...door pipes Step five connect outdoor eletric wire 1 Remove the screw on the right handle of outdoor unit and then remove the handle 1 Remove the wire clip connect the power connection wire and signal control wire only for heating unit to the wiring terminal according to the color fix themwith screws Note the wiring board is for reference only please refer to the actual one 3 Pretighten the union n...

Страница 36: ......

Страница 37: ...ins in 0 1 MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent 1 With a leakage detector check if there is leakage 2 If leakage detector is not available please use soap water for leakage detection Apply soap water at the su...

Страница 38: ......

Страница 39: ...pe and max rising difference Cooling capacity Max length of connection pipe Max rising difference 20 10 9000Btu h 2637W 20 10 12000Btu h 3516W 25 10 18000Btu h 5274W 24000Btu h 7032W Cooling capacity Max length of connection pipe Max rising difference 25 10 30 10 30 20 28000Btu h 8204W 36000Btu h 10548W 30 20 42000Btu h 12306W 30 20 48000Btu h 14064W ...

Страница 40: ......

Страница 41: ...er F Inspection Check the quality of expanding port If there is any blemish expand the port again according to the steps above 6 6 35 1 4 Note A varies according to the diameter please refer to the sheet below B Remove the burrs Remove the burrs with shaper and prevent the burrs from getting into the pipe C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor c...

Страница 42: ......

Страница 43: ...temperature On Off or Mode is shielded by the remote monitor Turbo function Memory function the indoor unit resumes the original setting after power failure and power recovery Blinks under ON status of the unit without touching any button Energy saving function not available for this unit Ambient Preset temperature value Blow function Time value Cooling mode Sleep function only Sleep 1 Fan mode Lo...

Страница 44: ......

Страница 45: ...n off button has been pressed again 3 2 Mode Setting When the unit is on press Mode to change operating modes in the following se quence 3 3 Temperature Setting Press or to increase decrease the preset temperature Hold either button down to increase or decrease the temperature by 1 every 0 5 sec as shown in Fig 6 In the Cool Dry Fan or Heat mode the temperature setting range is 16 30 In Auto mode ...

Страница 46: ......

Страница 47: ...er button is held down the time setting will increase decrease by 0 5 hr every 0 5 sec Fig 8 Setting Timer When Unit Is on Turn on the unit without setting timer Press Timer button to set Press on to set the timer time Press on Enter Cancel to exit the timer mode Press Timer button to cancel timer setting ...

Страница 48: ......

Страница 49: ... 1 hr and 1 after another 1 hr After that the unit will continue to run at this temperature When running in the Heat mode the temperature will decrease by 1 when the unit has been in Sleep 1 for 1 hr and 1 after another 1 hr After that the unit will continue to run at this temperature How to set the Sleep function is shown in Fig 10 3 7 Sleep Setting Turn on the unit without turning on sleep Press...

Страница 50: ......

Страница 51: ...n to enter the E heater setting interface Press Enter Cancel to cancel this function If the E heater function is not activated press Function to enter the E heater setting interface Press Enter Cancel to turn it on How to set this function is shown in Fig 12 10 10 Auxilliary electric hea ting function is automati cally on in Heating mode Press Function button into this function Press Function unti...

Страница 52: ......

Страница 53: ...ry switch When the unit is off press Mode and at the same time for 5 sec to switch between Memory On and Memory Off When this function is activated Memory will be displayed If this function is not set the unit stays off after a power failure and power recovery Memory recovery If this function has been set for the wired remote control the wired remote control after power failure will resume its ori...

Страница 54: ......

Страница 55: ... line from the installation holes and then pass it through the rectangular hole behind the soleplate on the wired remote control 3 Attach the wired remote control soleplate to the wall over the installation hole and then affix it with M 4X25 screws 4 Insert the twisted four core pair line into the slot on the wired remote control and then buckle the front panel and the soleplate together 5 Finally...

Страница 56: ......

Страница 57: ... P5 Compressor demagnetization protection Over phase current protection HE H7 PFC protection Compressor desynchronizing HC H5 IPM temperature protection IPM current protection P8 LD Over power protection Compressor phase loss reversal protection L9 F8 System charge short age or blockage protection Frequency restricted reduced with whole unit current protection F0 EN Capacitor charging error Freque...

Страница 58: ......

Отзывы: