![Gree GWH18YE-S6DBA2A/I Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/gree/gwh18ye-s6dba2a-i/gwh18ye-s6dba2a-i_service-manual_2260560087.webp)
Service Manual
4. ODU Fan M o to r C a n 't O perate
Possible causes
Discriminating method (air conditioner status)
Troubleshooting
Wrong wire connection, or poor
connection
Check the wiring status according to circuit
diagram
Connect wires according to wiring diagram to
make sure all wiring terminals are connected
firmly
Capacity of the ODU fan motor is
damaged
Measure the capacity of fan capacitor with an
universal m eter and find that the capacity is out of
the deviation range indicated on the nameplate of
fan capacitor.
Replace the capacity of fan
Power voltage is a little low or
high
Use universal m eter to measure the power supply
voltage. The voltage is a little high or low
Suggest to equip with voltage regulator
Motor of outdoor unit is damaged
When unit is on, cooling/heating performance
is bad and ODU com pressor generates a lot of
noise and heat.
Change com pressor oil and refrigerant. If no
better, replace the com pressor with a new one
5. C o m p re s s o r C a n 't O perate
Possible causes
Discriminating method (air conditioner status)
Troubleshooting
Wrong wire connection, or poor
connection
Check the wiring status according to circuit
diagram
Connect wires according to wiring diagram to
make sure all wiring terminals are connected
firmly
Capacity of com pressor is
damaged
Measure the capacity of fan capacitor with an
universal m eter and find that the capacity is out of
the deviation range indicated on the nameplate of
fan capacitor.
Replace the com pressor capacitor
Power voltage is a little low or
high
Use universal m eter to measure the power supply
voltage. The voltage is a little high or low
Suggest to equip with voltage regulator
Coil of com pressor is burnt out
Use universal meter to measure the resistance
between com pressor terminals and it's 0
Repair or replace com pressor
Cylinder of com pressor is blocked Com pressor can't operate
Repair or replace com pressor
6. A ir C o n d itio n e r is Leaking
Possible causes
Discriminating method (air conditioner status)
Troubleshooting
Drain pipe is blocked
W ater leaking from indoor unit
Eliminate the foreign objects inside the drain
pipe
Drain pipe is broken
W ater leaking from drain pipe
Replace drain pipe
Wrapping is not tight
W ater leaking from the pipe connection place of
indoor unit
Wrap it again and bundle it tightly
7. A b n o rm a l S o u n d and V ib ra tio n
Possible causes
Discriminating method (air conditioner status)
Troubleshooting
When turn on or turn off the unit,
the panel and other parts will
expand and there's abnormal
sound
There's the sound of "PAPA"
Normal phenomenon. Abnormal sound will
disappear after a few minutes.
When turn on or turn off the unit,
there's abnormal sound due
to flow of refrigerant inside air
conditioner
Water-running sound can be heard
Normal phenomenon. Abnormal sound will
disappear after a few minutes.
Foreign objects inside the indoor
unit or there're parts touching
together inside the indoor unit
There's abnormal sound fro indoor unit
Remove foreign objects. Adjust all parts'
position of indoor unit, tighten screws and stick
damping plaster between connected parts
Foreign objects inside the outdoor
unit or there're parts touching
together inside the outdoor unit
There's abnormal sound fro outdoor unit
Remove foreign objects. Adjust all parts'
position of outdoor unit, tighten screws and
stick damping plaster between connected parts
Short circuit inside the magnetic
coil
During heating, the w ay valve has abnormal
electrom agnetic sound
Replace magnetic coil
Abnormal shake of compressor
Outdoor unit gives out abnormal sound
Adjust the support foot mat of compressor,
tighten the bolts
Abnormal sound inside the
compressor
Abnormal sound inside the compressor
If add too much refrigerant during maintenance,
please reduce refrigerant properly. Replace
com pressor for other circumstances.
84
£
Installation and Maintenance
Содержание GWH18YE-S6DBA2A/I
Страница 10: ...Service Manual Technical Information 7 ...
Страница 24: ...Service Manual Technical Information 21 ...
Страница 58: ...Service Manual 8 Installation 8 1 Installation Dimension Diagram Installation and Maintenance 55 ...
Страница 76: ...Service Manual 5 C om m unica tion M alfunction E6 Installation and Maintenance 73 ...
Страница 77: ...Service Manual 6 M a lfu nction o f d e tecting plate W IFI JF Installation and Maintenance ...
Страница 83: ...Service Manual 80 Installation and Maintenance ...