10. TEMP b u tto n
Press this button, you can see indoor set tem perature, indoor am bient tem perature or outdoor am bient tem perature on indoor unit's
display. The setting on remote controller is selected circularly as below:
controller, tem perature indicator on indoor unit displays outdoor ambient temperature. 3s later it will return to the setting tem prature or it
depends on the other received signal within 3s.
Attention: W hen displaying the outdoor ambient, the displaying range is 32-99°F and 0-60°C.W hen it goes beyond the range, it keeps the
threshold data (the smallest— 0°C or 32°F and the largest 99°F or 60°C).
W arm tips: W hen operating buttons on the cover please make sure the cover is cl osed completely.
11. - ^ / ^
b u tto n (T h is fu n c tio n is o n ly a v a ila b le fo r s o m e m od e ls)
Press this button to achieve the on and off of healthy and scavenging functions in operation status.Press this button for the first
time to start scavenging function;LCD displays“ ^
”.Press the button for the second time to start healthy and scavenging functions
sim ultaneously;LCD displays“ ^
”and “^ - ” .Press this button for the third time to quit healthy and scavenging functions simultaneously.
Press the button for the fourth time to start healthy function; LCD display“^ - ” .Press this button again to repeat the operation above.
12. I FEEL b u tto n
Press this button once, to turn on the I FEEL function, then the figure of "I FEEL" will be displayed, after every press of other function
button, every 200ms to send I FEEL once, after this function started,the remote control will send tem perature to the main un it in every 10
minutes.When repress this button, this function will be turned off.
13. LIGHT b u tto n
Press this button at unit On or Off status,Light On and Light Off can be set up.After powered on, Light On is defaulted.
14. X-FAN b u tto n
Pressing X-FAN button in COOL or DRY mode,the icon ^
is displayed and the indoor fan will continue operation for 2 minutes in order
to dry the indoor unit even though you have turned off the unit.After energization, X-FAN OFF is defaulted.X-FAN is not available in
AUTO,FAN or HEAT mode.
15. QUIET b u tto n
Press this button,the Quiet status is under the Auto Quiet mode (display" ^ " and “A uto”signal ) and Quiet mode(display " £ i)" singal) and
Quiet OFF(there is no signal of " £ } " displayed),after powered on,the Quiet OFF is defaulted. Under the Quiet mode (Display "
"signal),
the fan speed is not available.
16. SLEEP b u tto n
• Press this button, can select Sleep 1 (
), Sleep 2 (
),Sleep 3 (
) and cancel the Sleep, circulate between these, after
electrified, Sleep Cancel is defaulted.
•S le e p 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour, the main unit setting temp erature will increase
1°C(1°F~2°F), 2 hours,setting tem perature increased 2°C(3°F~4°F), the unit will run at this setting temperature; In Heat mo de: sleep status
after run for one hour, the setting tem perature will decrease 1°C(1°F~2°F), 2 hours, setting tem perature will decrease 2°C(3°F~4°F), then
the unit will run at this setting temperature.
•S le e p 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep tem perature curve.
In Cool mode:
(1) W hen setting the initial temperature 16~23°C(61°F~74°F), after turned on Sleep function, the temperature will be increased 1°C(1°F~2°F)
in every hour,after 3°C(5°F~6°F) the tem perature will be maintained, after 7hours,the tem perature will be decreased 1°C(1°F~2°F), after
that the unit will keep on running under this temperature;
(2) W hen setting the initial temperature 24~27°C(75°F~81°F), after turned on Sleep function, the temperature will be increased 1°C(1°F~2°F)
in every hour,after 2°C(3°F~4°F) the tem perature will be maintained, after 7hours,the tem perature will be decreased 1°C(1°F~2°F) ,
after
that the unit will keep on running under this temperature;
(3) W hen setting the initial temperature 28~29°C(82°F~85°F), after turned on Sleep function, the temperature will be increased 1°C(1°F~2°F)
in every hour, after 1°C(1°F~2°F) the tem perature will be maintained, after 7hours,the tem perature will be decreased 1°C(1°F~2°F) , after
that the unit will keep on running under this temperature;
(4) W hen setting the initial tem perature 30°C(86°F), under this tem perature setting, after 7hours, the tem perature will be decreased
1°C(1°F~2°F), after that the unit will keep on running under this temperature;
In Heat mode:
(1) Under the initial presetting tem perature 16°C(61°F), it will run under this setting tem perature all along.
(2) Under the initial presetting temperature17~20°C(62°F~68°F), after Sleep function started up, the temperature will decrease 1°C(1°F~2°F)
in every hour, after 1°C(1°F~2°F) decreased, this tem perature will be maintained.
(3) Under the initial presetting tem perature 21~27°C(69°F~81°F), after Sleep function started up, the tem perature will decrease
1°C(1°F~2°F) in every hour,after 2°C(3°F~4°F) decreased, this tem perature will be maintained.
(4) Under the initial presetting tem perature 28~30°C(82°F~86°F), after Sleep function started up, the tem perature will decrease
1°C(1°F~2°F) in every hour, after 3°C(5°F~6°F) decreased, this tem perature will be maintained.
W hen selecting " 0 " with remote controller or no display, tem perature indicator on indoor unit displays set temperature; W hen selecting
" {Tf " with remote controller,temperature indicator on indoor unit displays indoor ambient temperature; W hen selecting " Q i " with remote
16
0
Technical Information
Содержание GWH18YE-S6DBA2A/I
Страница 10: ...Service Manual Technical Information 7 ...
Страница 24: ...Service Manual Technical Information 21 ...
Страница 58: ...Service Manual 8 Installation 8 1 Installation Dimension Diagram Installation and Maintenance 55 ...
Страница 76: ...Service Manual 5 C om m unica tion M alfunction E6 Installation and Maintenance 73 ...
Страница 77: ...Service Manual 6 M a lfu nction o f d e tecting plate W IFI JF Installation and Maintenance ...