![Gree GWH18YE-S6DBA2A/I Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/gree/gwh18ye-s6dba2a-i/gwh18ye-s6dba2a-i_service-manual_2260560020.webp)
Service Manual
•S le e p 3- the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep setting status, at this
time, the time of remote control will display "Ih o u r ", the setting tem perature "88" will display the corresponding tem perature of last setting
sleep curve and blink (The first entering will display according to the initial curve setting value of original factory);
(2) Adjust "+" and "-" button, could change the corresponding setting tem perature, after adjusted, press "Trubo "button for confirmation;
(3) A t this time, Ih o u r will be autom atically increased at the tim er postion on the remote control, (that are "2hours" or "3hours" or "8hours "),
the place of setting tem perature "88" will display the corresponding tem perature of last setting sleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8hours tem perature setting finished, sleep curve setting finished, at this time, the remote
control will resume the original tim er display;temperature display will resume to original setting temperature.
•S le e p 3 - the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user individuation sleep setting
status, but do not change the temperature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there is no button pressed, the sleep curve setting status will
be autom atically quit and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF" button, "Mode"
button, "Timer" button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
17. A b o u t X-FAN fu n c tio n
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
(1)Having set X-FAN function on: A fter turning off the unit by pressing ON/OFF button indoor fan will continue running for about 2 min. at
low speed. In this period, press X-FAN button to stop indoor fan directly.
(2)Having set X-FAN function off: A fter turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
18. A b o u t AU TO RUN
W hen AUTO RUN mode is selected, the setting tem perature will not be displayed on the LCD, the unit will be in accordance with the room
temp. autom atically to select the suitable running method and to make ambient comfortable.
19. A b o u t tu rb o fu n c tio n
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. approachs the preset temp.
as soon as possible.
20. A b o u t lo ck
Press + and - buttons sim ultaneously to lock or unlock the keyboard. If the remote controlleris locked, the icon ^ will be displayed on it, in
which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
21. A b o u t s w in g up and do w n
(1)Press swing up and down button continuously more than 2s,the main unit will swing back and forth from up to down, and then
loosen
the button, the unit will stop swinging and present position of guide louver will be kept immediately.
(2)Under swing up and down mode, when the status is switched from off to ^1 , if press this button again 2s later, ^1 status will switch
to off status directly; if press this button again within 2s,the change of swing status will also depend on the circulation sequence stated
above.
22. A b o u t s w in g le ft and rig h t
(1)Press swing left and right button continuously more than 2s,the main unit will swing back and forth from left to right, and then loosen the
button, the unit will stop swinging and present position of guide louver will be kept immediately.
(2)Under swing left and right mode, when the status is switched from off to
, if press this button again 2s later,
status will switch
to off status directly; if press this button again within 2s,the change of swing status will also depend on the circulation sequence stated
above.
23. A b o u t s w itc h betw een F a h re n h e it and C e n tig ra d e
Under status of unit off, press MODE and - buttons sim ultaneously to switch °C and °F.
24. C o m b in a tio n o f " TE M P " and "C L O C K " b u tto n s : A b o u t E n e rg y -s a vin g F u n ctio n
Press “TEM P” and “CLOCK” simultaneously in COOL mode to start energy-saving function.Nixie tube on the remote controller displays “SE”.
Repeat the operation to quit the function.
25. C o m b in a tio n o f " TE M P " and "C L O C K " b u tto n s : A b o u t 8°C(46°F) H eating F u n ctio n
Press “TEM P” and “C LO C K” sim ultaneously in HEAT mode to start 8°C(46°F) Heating Function.Nixie tube on the remote controller
displays" ® "and a selected tem perature of “8°C ” (46°F if Fahrenheit is adopted). Repeat the operation to quit the function.
26. A b o u t A u to Q u ie t fu n c tio n
W hen auto quiet function is selected:
(1)Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or when indoor ambient temperature<28°C(82°F), indoor
fan will operate at notch 2 speed or quiet mode according to the comparison between indoor ambinet tem perature and set temperature.
(2)Under heating mode: indoor fan operates at notch 3 speed or quiet mode according to the comparison between indoor ambient
tem perature and set temperature.
(3)Under dry, fan mode: indoor fan operates at quiet mode.
(4)Under auto mode: the indoor fan operates at the auto quiet mode according to actual cooling, heating or fan mode.
27. A b o u t S leep fu n c tio n
Under the Fan and Auto mode, the Sleep function cannot be set up, under Dehumidify mode, only Sleep 1 can be selected.Select and
enter into any kind of Sleep mode, the Quiet function will be attached and stared, different Quiet status could be optional and turned off.
Technical Information
%
17
Содержание GWH18YE-S6DBA2A/I
Страница 10: ...Service Manual Technical Information 7 ...
Страница 24: ...Service Manual Technical Information 21 ...
Страница 58: ...Service Manual 8 Installation 8 1 Installation Dimension Diagram Installation and Maintenance 55 ...
Страница 76: ...Service Manual 5 C om m unica tion M alfunction E6 Installation and Maintenance 73 ...
Страница 77: ...Service Manual 6 M a lfu nction o f d e tecting plate W IFI JF Installation and Maintenance ...
Страница 83: ...Service Manual 80 Installation and Maintenance ...