2. M a lfu n c tio n o f B lo c k e d P ro te c tio n o f IDU Fan M o to r H6
Main detection points:
• Sm oothlyls the control terminal of PG motor connected tightly?
• Sm oothlyls the feedback interface of PG motor connected tightly?
• The fan motor can't operate?
• The m otor is broken?
• Detectioncircuit of the mainboard is defined abnormal?
Malfunction diagnosis process:
/-■''Under power-off condition>--
check whether the wiring terminal
between indoor fan and main
board is loose.
Reinsert the wiring
terminal of indoor fan.
Turn unit on "
to check whether the "
malfunction is
eliminated.