U-Match Series DC Inverter Service Manual
134
Removal and Installation of Drainage Pump
Step
Illustration
Handling Instruction
1. Loosen the screws
fixing the water tray
Use screwdriver to loosen the screws
fixing the water tray.
2. Remove the water tray
Remove the water pump and replace it.
3. Pull out the water outlet
pipe and loosen the
screws fixing the water
pump.
Pull out the water outlet pipe and use
screwdriver to loosen the screws fixing the
water pump.
4. Take out the pump and
replace it
Take out the pump and replace it