Super Free Match
Service Manual
CONTROL
40
of
.
If the swing function is deactivated when the air guide louver is swing up and down, it will stop at the current
position indicates that the air guide louver swings up and down among all five positions.
indicates that the air guide louver swings up and down among all five positions.
12)
X-FAN
Pressing X-FAN button in COOL or DRY mode, the icon
is displayed and the indoor fan will continue
operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit.
After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
13)
TEMP
It can be decided by pressing this button which temperature will be displayed, indoor set temperature, or
indoor ambient temperature. When the indoor unit is powered on, the indoor set temperature will be displayed,
while if the status is changed to, the indoor ambient temperature will be displayed. However, the indoor set
temperature will be displayed again when the controller receives other remote controls signals. Without setting
this function, the default is the indoor set temperature.
14)
TIMER OFF
TIME OFF can be activated by pressing this button, with “OFF” blinking. The method of setting is the same
as that for TIMER ON.
15)
TURBO
In Cool or Heat mode, pressing this button can activate or deactivate this function. When this function is on,
its symbol will be displayed. Any change of either mode or fan speed will make this function canceled
automatically.
16)
SLEEP
Sleep On and Sleep Off can be selected by pressing this button. After powered on, the default is Sleep Off.
After the unit is turned off, the Sleep function is canceled. When the sleep function is set already, the symbol will
be displayed. And at this time, the time of timer can be adjusted. Under Fan and Auto modes, this function is not
available.
17)
LIGHT
Light On and Light Off can be set by pressing this button when the unit is at On or Off status. After powered
on, the default is Light On.
3.2.2 Guide for General Operation
1) After powered on, press ON/OFF and then the unit will start to run.
Note:
when powered off, the guide louver of the main unit will close automatically.
2) Press MODE to select the desired running mode.
3) Press
+
or
-
to set the desired temperature (it is unnecessary to set the temperature under the AUTO
mode.)
4) Press FAN to set the fan speed, Auto, Low, Medium, or High.
5) Press
to select the swing angle.
3.2.3 Guide for Optional Operation
1)
About X-FAN
This function indicates that moisture in the evaporator of the indoor unit will be dried after the unit is stopped
to avoid mould.
Содержание GKH(12)BA-K3DNA1A/I
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201405 CENTRAL AIR CONDITIONERS...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT...
Страница 27: ...Super Free Match Service Manual CONTROL 23 CONTROL...
Страница 28: ...Super Free Match Service Manual CONTROL 24 Control 1 OPERATION FLOWCHART...
Страница 30: ...Super Free Match Service Manual CONTROL 26 1 2 Heating Operation...
Страница 64: ...Super Free Match Service Manual INSTALLATION 60 INSTALLATION...
Страница 111: ...Super Free Match Service Manual INSTALLATION 107 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2...
Страница 122: ...Super Free Match Service Manual MAINTENANCE 118 MAINTENANCE...
Страница 144: ...Super Free Match Service Manual MAINTENANCE 140 4 2 3 BU module FXB3A K...
Страница 145: ...Super Free Match Service Manual MAINTENANCE N 141 FXB5A K...
Страница 193: ...Super Free Match Service Manual MAINTENANCE N 189 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I...
Страница 207: ...JF00301896...