Super Free Match
Service Manual
INSTALLATION
100
6.5
Connection of Outdoor Unit Refrigerant Pipe
NO.
①
②
③
④
Name
Coping plate
Rear side plate
Front side plate
Gas side stop valve
NO.
⑤
⑥
⑦
Name
Liquid side stop valve
Right connection board
Front connection board
NO.
A
B
C
D
Name
Front connection
Bottom connection
Side connection
Rear connection
1)
Unscrew the coping plate, front side plate, right connection board and front connection board.
2)
The refrigerant pipes can be installed in four directions, please choose the proper direction.
3)
Knock the holes in the plate of the chosen direction with the drill and hammer.
4)
Connect the pipes to the stop valves.
5)
Bend the pipes to go through the knockout holes.
6)
Cover the through-holes with sealing materials to prevent the water, dust or small animals going into the
outdoor unit.
6.6
Installation of Piping Adapter
If the piping connection size of BU module does not match with that of the outdoor unit and indoor units, it
should prevail with the piping connection size of the outdoor unit and indoor units. Install the optional piping
adapters to the BU module, so that the piping connection size of BU module can match with that of the outdoor
unit and indoor units.
1)
Piping adapter(Optional
accessories
)
NO. Name Port
A
(mm)
Port B
(mm)
1
Φ
15.9
→Φ
19.05
Φ
15.9
Φ
19.05
2
Φ
9.52
→Φ
12.7
Φ
9.52
Φ
12.7
3
Φ
9.52
→Φ
15.9
Φ
9.52
Φ
15.9
4
Φ
6.35
→Φ
9.52
Φ
6.35
Φ
9.52
Содержание GKH(12)BA-K3DNA1A/I
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201405 CENTRAL AIR CONDITIONERS...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT...
Страница 27: ...Super Free Match Service Manual CONTROL 23 CONTROL...
Страница 28: ...Super Free Match Service Manual CONTROL 24 Control 1 OPERATION FLOWCHART...
Страница 30: ...Super Free Match Service Manual CONTROL 26 1 2 Heating Operation...
Страница 64: ...Super Free Match Service Manual INSTALLATION 60 INSTALLATION...
Страница 111: ...Super Free Match Service Manual INSTALLATION 107 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2...
Страница 122: ...Super Free Match Service Manual MAINTENANCE 118 MAINTENANCE...
Страница 144: ...Super Free Match Service Manual MAINTENANCE 140 4 2 3 BU module FXB3A K...
Страница 145: ...Super Free Match Service Manual MAINTENANCE N 141 FXB5A K...
Страница 193: ...Super Free Match Service Manual MAINTENANCE N 189 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I...
Страница 207: ...JF00301896...