DC Inverter U-match Series Duct Type Unit
52
Operation after connecting the power:
(1) If all the above works are finished, power on the unit.
(2) If the outside temperature is more than 30°C, heating mode
can’t be enabled.
(3) Make sure the indoor and outdoor units can run normally.
(4) If there’s sound of liquid shock when the compressor is running,
then stop the air conditioner immediately. Wait until the electric
heating belt is heated enough, and then restart the air
conditioner.
(5) Feel the air flow of the indoor unit to see if it is normal.
(6) Press the swing button or speed control button on remote
control or wired control to see if the fan can run normally.
Notice:
①
If you use remote control to turn off the unit and then
immediately turn the unit on again, compressor will need 3min
to restart. Even if you press “ON/OFF” button on the remote
control, it won’t be started up right away.
②
If there’s no display on the wired control, it’s probably because
the connection wire between the indoor unit and wired control is
not connected. Please check again.
4 Operation specification
Refer to the wired controller or remote controller manual.