DC Inverter U-match Series Duct Type Unit
25
Screw on the flare nut of the flaring connecting pipe on the outdoor
unit valve. The method of screwing the flare nut is the same with that for
indoor unit.
3.2.3.5 Thermal Insulation of Pipe Joint (Only for indoor unit)
Stick coupler heat insulation (large and small) to the place where
connecting pipes.
Reference A
Coupler heat insulation
(large) on the pipe
Front outlet
Reference A:
Cover this portion with heat
insulating material also without fail
Coupler heat
insulation (small)
on the pipe
No gap
Heat insulation pipe
Liquid pipe
Gas pipe
3.2.3.6 Sealing of the Knock-off Hole
As for the built-in valve model, during the installation process for
connection pipe, when the connection pipe is passing through the
knock-off hole, conduct sealing with insulated cotton in the knock-off
hole of outdoor unit to prevent small animals from entering. See the
following figures.