30
defaulted to be the one on the left side (electric box side).
(8) When using the drain port on the right side of the unit, reinstall
the drain cap to the left side drain port. See the following figure.
(9) Be sure to insulate where the drain port and the drain hose is
connected. See the following figure.
(10) The unused drain port also should be insulated properly. See
the following figure.
(11) There is adhesive on one side of the insulation so that after
removing the protective paper over it the insulation can be
directly attached to the drain hose.
3.2.6.2 Outdoor Side Drainage Pipe
(1) If the outdoor unit is underneath the indoor unit, arrange the
pipeline according to the following diagram.
1) Drain hose should be placed on the ground and its end
should not be immersed into water. The whole pipeline