21
UCP
-
3901
User Manual
CPU status LED
Future use.
REF status LED
Shows the following state:
•
Flashing Green:
Watchdog timer OK.
Densité status LED Shows the following states (status indication priority
a
):
•
Red
(level 6): Card is powering up.
If solid red persists (>6 seconds), a hardware failure has been
detected: the card’s CPU could not boot. This may be the result of
the UCP
-
3901 Card not being equipped with its Micro-SD card or
the Micro-SD card is not properly inserted. See
•
Yellow
(level 2): Card is booting.
•
Green
(level 1): Card has finished booting. Normal operation.
•
Flashing Yellow
(level 5): Card has been selected for local control
using the Densité frame’s control panel by having pressed the
card’s
SELECT
button. Press the card’s
SELECT
button again to
remove local control.
•
Alternating Red / Green
(level 4): Card’s firmware is being
upgraded.
•
Flashing Red
(level 3): Indicates one of the following possible
errors:
• The presence of the rear panel has not been detected.
• Ensure the card is inserted into the correct Densité frame
slot that lines-up with the rear panel.
• Ensure the rear panel is installed. See
• Fan Error: the card’s fan is not spinning, or is spinning too
slowly, or the fan cable is disconnected. Urgent maintenance
procedures must be considered: If this alarm has been raised,
the fan on the UCP
-
3901 Card may have to be replaced. See
Cooling Fan Operational Assessment
SELECT Button
Press to select this card for local control using the Densité frame’s
control panel. Through the Densité frame’s control panel, you can set
the card’s IP addresses of the Ethernet interfaces. See
using the Densité frame control panel to set the Card’s IP Addresses
USB Socket
Unused.
Reset Button
Performs a hardware reset of the card. Only use this feature during off
hours as this will result in an outage until the card has returned to
normal operation (Densité status LED becomes green).
a.Level 1 = lowest priority, greater than level 1 = higher priority. How the status indication priority
operates: The Densité status LED only shows the highest active priority condition at any given time.
When the condition that triggers a status is removed or is rectified, then the next lower status
indication priority that is currently active is shown.
Item
Description
Содержание UCP-3901
Страница 1: ...User Manual 13 03084 010 M00 AB 2020 10 27 UCP 3901 UNIFIED COMPUTE PROCESSOR FOR DENSITÉ ...
Страница 18: ...18 Introduction Supported SFP28 Cartridges ...
Страница 32: ...32 UCP 3901 Card Installation and Operation Remote control using RollCall ...
Страница 36: ...36 Connections and Cabling Cabling to Support SMPTE ST 2022 7 with a UCP 3901 ...
Страница 122: ...122 Essence Processing SDC SFP Configuration ...
Страница 202: ...202 Maintenance Troubleshooting Keep Fiber Connections Clean ...