
246
KARRERA K-FRAME — Installation & Service Manual
Section 7 — Maintenance
immediately visible after a power cycle and present until the application
software writes the first data to the character displays
Example codes are shows in
Creating Compact Flash Cards
The Control Panels each use their own specially formatted and partitioned
Compact Flash (CF) card. The system cannot use blank CF cards directly
formatted by a PC or other device.
The K-Frame Switcher Installer program is used to format, partition, and
load boot files onto system CF cards. Once prepared in this manner, the
appropriate GV Switcher software (Control Panel) will need to be installed
Table 17. Control Panel Board Boot Display Codes
Digit
3
2
1
0
Digit Zero shows the link and FPGA boot status
*
1. Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
+
1. Module interface link is working (normal/default).
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary.
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over application area (normal/default).
!
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary!.
Digit 1 shows the lower number of the FPGA firmware version.
Digit 2 shows the middle number of the FGPA firmware version.
Digit 3 shows the upper number of the FPGA firmware version. (X1 always shows “!” to see the difference to the released versions).
Table 18. Control Panel Module Boot Display Codes Examples
Digit
0
3
7
*
1. Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
+
1. Module interface link is working (normal/default).
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary.
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over application area (normal/default).
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
!
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over factory area --> application area damaged, reprogramming necessary.
3. FPGA firmware version is 038 (DS1281.038).
!
3
5
*
1. Module interface link is working (normal/default).
2. FPGA was loaded over factory area because X1 doesn't have a application area (normal/default).
3. FPGA firmware version is X1 and 35 (DS5831.035).
!
3
5
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over factory area because X1 doesn't have a application area (normal/default).
3. FPGA firmware version is X1 and 35 (DS5831.038).
Содержание KARRERA K-FRAME
Страница 12: ...12 KARRERA K FRAME Installation Service Manual Contents ...
Страница 30: ...30 KARRERA K FRAME Installation Service Manual Regulatory Notices ...
Страница 56: ...56 KARRERA K FRAME Installation Service Manual Section 2 Control Surface Installation ...
Страница 152: ...152 KARRERA K FRAME Installation Service Manual Section 5 Basic Configuration Figure 104 FBWF Manager ...
Страница 266: ...266 KARRERA K FRAME Installation Service Manual Appendix B Field Replaceable Units ...
Страница 278: ...278 KARRERA K FRAME Installation Service Manual Index ...