7 ELECTRICAL ADJUSTMENTS
(12) Adjust the 450g-pen force. If the measured value is within the specification range (450±20 g) or if you
have input the recorded value, press the ENTER key to store the setting. (Only for the CE5000-120.)
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changes the temperature of the actuator and causes artificially lower readings. When this happens the
actual pen force may be higher than the specification. This is especially true for the upper pen force
adjustment.
(13) Press the NEXT key to complete this adjustment.
Specification of the actual pen force
Specified pen force
Actual force range
Remark
10 g
8 to 12 g
40 g
36 to 44 g
120 g
110 to 130 g
300 g
280 to 320 g
450 g
430 to 470 g
Only for the CE5000-120