Step 6
Lift the handle to disengage the catch and fully open the
combustion chamber door. Refer to Figure 10-5.
WARNING
The interlock on the combustion chamber door
automatically disconnects the power supply to the burner if
the door is opened.
IT DOES NOT IMMEDIATELY EXTINGUISH THE BURNER
FLAME.
If the burner door is opened during the operation of the
burner there can be a large uncontrollable flame from the
brazier.
Step 7
Hook one of the two carrying handles (supplied with the boiler)
under the front edge of the ash pan and carefully pull the ash pan
forward by about 300mm (12inches). Refer to Figure 10-6.
Step 8
Brush/scrape any ash resting on the burner into the ash pan
below.
Step 9
Using both of the carrying handles, one at the front and the other
at the back, carefully lift the ash pan out of the boiler. Refer to
Figure 10-7.
Do NOT use the centre cross bar of the ash pan as a
carrying handle.
Step 10
Safely dispose of the ash.
WARNING
Extreme care is required when emptying the ash pan as
smouldering ash could be present and can cause serious
damage to persons or property.
Ensure the ash is disposed of in a safe manner.
Step 11
Remove any remaining ash that may be left in the base of the
boiler before putting the ash pan back into the combustion
chamber.
Step 12
Close the combustion chamber door and ensure that the door
catch is fully engaged.
Remove the door handle and keep in a safe place for future use,
along with the carrying handles.
Figure 10-5: Opening combustion chamber door
Figure 10-6: Removal of ash pan from boiler
Figure 10-7: Lifting ash pan using carrying handles
15
Figure 10-7:
Lifting ash pan using carrying handles
Figure 10-5:
Opening combustion chamber door
Figure 10-6:
Removal of ash pan from boiler
Содержание Spira 5-18
Страница 19: ...19 This page is intentionally left blank...
Страница 95: ...95 13 Spare Parts 13 1 Boiler Figure 13 1 Boiler components exploded view...
Страница 106: ...106 Notes...
Страница 107: ...107 This page is intentionally left blank...