Section 14: Control Panel
Page 61
Table 14-4:
Control panel key
Key
Item
Description
1
Heat meter
Refer to Section 7.2 for further information
2
Electricity meter
Refer to Section 7.3 for further information
3
Overheat thermostat
The safety overheat thermostat will automatically switch off the boiler in the case of a control
malfunction causing overheating. If this occurs, the boiler will not light until the thermostat is reset.
To reset:
•
Unscrew the small plastic cap (refer to Figure 13-2)
•
Insert a small pointed implement into the hole and press the reset button
•
Replace the cap
If this condition continually repeats, contact your Service Engineer.
4
On / Off switch
This switch allows the hybrid unit to be switched off and back on as and when required. With this
switch set to OFF, neither the heat pump or the oil boiler will operate. This will override all heating
demands from the control system for the unit to start.
IMPORTANT: Setting this switch to OFF
DOES NOT
isolate the electrical supply to the heat pump
or the oil boiler. To fully isolate both heat pump and oil boiler unit, use the lockable external isolator
installed to provide power to the hybrid. Refer to Section 12 (electrical) for details of electrical
wiring.
5
Oil / Hybrid switch
This switch allows selection of either the 'hybrid' or 'oil' modes of operation, as follows:
•
Hybrid
- when the switch is set to this, the heat pump either operates alone or in conjunction
with the oil boiler, depending on air control thermostat setting.
•
Oil
- when the switch is set to this, only the oil boiler can operate.
Set the switch to this option if the oil boiler is to operate in a 'stand-alone' situation, i.e. if the
heat pump has not yet been installed, or it has been shut down for maintenance.
6
Fuse - heat meter (1 amp)
This fuse protects the electrical supply to the heat meter.
7
Fuse - heating controls (5 amps)
This fuse protects the electrical supply to the external heating system controls and the oil boiler.
8
Boiler control thermostat
This controls the boiler flow temperature level. It has two temperature settings (R1 and R2).
Refer to Section 15.6.1 (commissioning) for details on how to set the boiler control thermostat.
9
Air control thermostat
This monitors the ambient (outdoor) air temperature. It has two temperature settings (R1 and R2).
Refer to Section 15.6.2 (commissioning) for details on how to set the air control thermostat.
Figure 14-3:
Control panel
1
2
6
5
4
7
3
8
9
Содержание Aerona3 Series
Страница 57: ...Section 13 Flue System and Air Supply Page 57 Figure 13 8 Flue clearances...
Страница 77: ...Section 19 Spare Parts Page 77 Figure 19 4 15 21kW baffles Figure 19 5 21 26kW baffles...
Страница 84: ...Appendix A Page 84 Appendix A...
Страница 85: ...Appendix A Page 85...
Страница 86: ...Appendix A Page 86...
Страница 87: ...Appendix A Page 87...