Section 2: Technical Data
Page 8
2.1 Boiler Technical Data
Table 2-1:
Boiler technical data
Unit
HPIDAIR - 15/21kW
HPIDAIR2 - 21/26kW
Water content - oil boiler / heat pump (total)
litre
16.5 / 2.0 (18.5)
10.5 / 2.0 (12.5)
gallon
3.6 / 0.44 (4.04)
2.3 / 0.44 (2.74)
Weight - oil boiler and heat pump (empty)*
kg
270
272
lb
595
600
Weight - oil boiler and heat pump (full)*
kg
290.2
286.5
lb
639.8
631.6
Maximum heat output (Kerosene)**
kW
21
26
Btu/h
71 694
88 764
Heating system flow connection
1" BSP female
Heating system return connection
1" BSP female
Minimum flow rate (
∆
T=8°C)
litres/min.
15
Condensate connection
22 mm (only connect plastic pipe)
Waterside resistance (
∆
T=10°C)
mbar
26
Waterside resistance (
∆
T=20°C)
mbar
9.5
Maximum static head
metre
28
Minimum circulating head
metre
1
Boiler thermostat range
°C
65 to 78
Limit (safety) shut off temperature
°C
111 ± 3
Maximum hearth temperature
°C
Less than 50
Electricity supply
230/240V 1ph 50Hz fused at 5A
Burner motor power
Watts
90
Absorbed motor power
Watts
0.15
Starting current
Amps
2.0
Running current
Amps
0.85
Oil connection
¼" BSP male (on end of flexible tube)
Maximum operating pressure - sealed system
bar
2.5
Maximum operating pressure - pressure relief valve
bar
2.0
* Weight includes burner but excludes flue.
** Factory setting (maximum output). Refer to Section 2.4 for other boiler outputs.
2.2 Heat Pump Technical Data
For technical data relating to the heat pump, please refer to the Aerona³ installation and servicing instructions supplied with the heat pump.
2 Technical Data
Содержание Aerona3 Series
Страница 57: ...Section 13 Flue System and Air Supply Page 57 Figure 13 8 Flue clearances...
Страница 77: ...Section 19 Spare Parts Page 77 Figure 19 4 15 21kW baffles Figure 19 5 21 26kW baffles...
Страница 84: ...Appendix A Page 84 Appendix A...
Страница 85: ...Appendix A Page 85...
Страница 86: ...Appendix A Page 86...
Страница 87: ...Appendix A Page 87...