5.2 SET BURNER FOR EFFICIENT OPERATION
BURNER SETTING
Use burner settings in the table on page 18 (KLR) and 19 (KLF) or
operating decal as a guide to set burner, particularly for nozzle changes.
Those settings are only starting points for the adjustments and are not
meant as final settings.
On Beckett AFG burner, make sure the correct retention head and static
disk are installed on the burner for the desired firing rate. The head is held
in place by two screws at the end of the burner blast tube. From the burner
technical information table on page 18 (KLR) and 19 (KLF), the head is
always after the AFG designation and the static disk after the head. For
example, the AFG L2 3’’ 3/8 means an AFG chassis burner with a L2 head
and a static disk of 3’’ 3/8.
PUMP PRESSURE
Refer to the table on page 18 (KLR) and 19 (KLF) or operating decal.
AIR SETTING
Use air settings on page 18-19 as a guide to set air adjustment.
Those
settings are only starting points for the adjustments and are not meant
as final settings.
DRAFT REGULATOR
The draft regulator should be installed at least 3 flue pipe diameters from
breeching or elbow of the furnace.
SAMPLING HOLE
On smoke/vent pipe, drill a 3/8” round opening. The hole should be at least
2 flue pipe diameters from breeching or elbow of the furnace.
FRONT FLUE FURNACE ILLUSTRATION
Содержание KLF-100
Страница 7: ...7 KLR 200 DIMENSIONS Dimensions are in inches KLF 100 DIMENSIONS Dimensions are in inches...
Страница 22: ...22 Position of the ST9103A1028 Electronic Board KLR 100 and 200 KLF 100 KLF 200...
Страница 28: ...28 8 0 ELECTRICAL WIRING DIAGRAMS HEATING COOLING KLR KLF RIELLO...
Страница 29: ...29 HEATING COOLING For more informations see next page...
Страница 30: ...30 GeniSys control schematic with the ST9103 Board...
Страница 31: ...31 HEATING ONLY RIELLO BECKETT...
Страница 34: ...34 KLR 200 EXPLODED PARTS VIEW Detail A ELB A0 0008 00 Electric box...