5.0 BURNER INSTALLATION AND SPECIFICATIONS
5.1 ASSEMBLY & INSTALLATION OF BURNER
ASSEMBLY
Check that the burner model is correct for furnace rating required.
Assemble as per burner manufacturer’s instructions.
SELECT NOZZLE
Select oil input, nozzle and burner configuration as shown on furnace
operating decal.
INSTALL NOZZLE
Install selected nozzle, check for clean seating and tighten in nozzle
adaptor.
ELECTRODES
See burner manufacturer’s instructions for correct setting
INSERTION
Tighten top nut first so burner tips down slightly. The burner
MOUNT BURNER
is always installed in an upright position by four (4) nuts.
PUMP BY-PASS
For one pipe system factory setting (no
PLUG
plug).
WIRING
Refer to wiring diagram for correct burner
connections (see page 28, 29 or 31).
THERMOSTAT
Connect the thermostat wires to the fan timer
control board (ST9103).